Chapter 1 Cat 1 Stop with Guardlocking Interlock (TLS-ZR or 440G-LZ)
Schematic
Figure 2 - Schematic
PowerFlex PF525 Settings
Table 1 lists some of the parameter settings for this application. This is not a
complete list of parameters for the PF525. Y
ou can set many other parameters to
make this application successful.
Table 1 - Parameter Settings
05
CR30
020100 03 04
A1 15 20 2116
06
18A2
07
19
08 10 11
12 13 14
09
17
+24V DC
24V DC Com
Reset
Red
Pink
Green
White
Blue
Grey
Yellow
Brown
Safety
Gate
Safety
TLS-ZR
440G-TZS21UPRH
889D-F8AC-2
440C-CR30-22BBB
Gate
Unlocked
Gate
Lock/
Unlock
Gate control
power supply
Gate control
circuit
M
4 Gnd
S1
S2
1 Stop
L1 L2 L3
PowerFlex
525
2 Start
R5
R6
RTS
UWV
Parameter Name Value Unit/Description
P042 Decel Time 3 Seconds
P045 Stop Mode 0 Stop and Clear Fault
P046 Start Source 2 Digital Input Terminal Block
P047 Speed Reference
1
1 Drive Pot
T081 Relay 2 2 Motor Running
Motor is receiving power from the drive.
T105 Safety Open En 1 Fault Disable