12 Rockwell Automation Publication 440C-WD001C-EN-P - June 2015
Chapter 1 Cat 1 Stop with Guardlocking Interlock (TLS-ZR or 440G-LZ)
Example Bill of Materials
Table 3 - Bill of Materials
Safety Rating
The safety function that is performed by the guard locking interlock meets the
safety performance requirements of SIL CL2 per IEC 61061:2012 and SIL 2 per
IEC 61508:2005 and has a Category 3 structure that can be used in systems
requiring Performance Levels up to PLd per ISO 13849-1: 2006. The circuit
executes a Stop Category 1.
Item Product Description Qty
1 440C-CR30-22BBB Guardmaster® 440C-CR30 Software Configured Safety Relay
PLe SIL 3, 22 Safety I/O, embedded serial port, USB programming
port, 2 plug-in slots, 24V DC
1
2 440G-TZS21UPRH Guard Locking Switch - TLS-Z GD2
Solenoid Voltage: 24V AC/DC
Contacts (Safety and Aux): 2 x PNP (0.2A max.), 1 x PNP (0.2A max.)
Actuator: Fully-flex
Conduit Entry: 8-pin micro (M12)
1
2.1 889D-F8AC-5 DC Micro (M12) Cordset
Female, straight, 8-pin, PVC cable, yellow, unshielded, 22 AWG, IEC
color coded, no connector, 5 m (16.4 ft)
1
3 800FM-P4MN3R 800F Pilot Light
Metal (IP66, 4/13, IP66), red, standard pack
1
4 800FM-SM22MX10 800F 2-position Selector Switch
Metal, maintained, black, standard knob, standard orientation,
1 N.O. contact block, standard pack
1
5 800FM-F611MX10 800F Push Button
Metal, flush, blue, R, metal latch mount, 1 N.O. contact, 0 N.C.
contacts, standard, standard pack
1
6 24B-V2P5A104AA-ND-P3 PowerFlex 525 Pre-engineered FasTrac, with Embedded
EtherNet/IP™ and Safety
120VAC, 1-phase, 0.5 Hp, 0.4 kW normal duty; 0.5 Hp, 0.4 kW heavy
duty, Type 1 / IP20, no filter, without bypass, without reactor, motor
circuit protector (-P3)
1
7 800FM-F301 800F Push Button
Metal, flush, green, START, standard pack
1
8 800FM-E402 800F Push Button
Metal, extended, red, STOP, standard pack
1