14 Rockwell Automation Publication 440C-WD001C-EN-P - June 2015
Chapter 2 Cat 1 Stop with GuardShield Light Curtain, T-15 Interlock, E-Stop, and PowerFlex 525
Schematic
Figure 5 - Schematic
PowerFlex PF525 Settings
Table 4 shows a list of some of the parameter settings for this application. The list
is not a complete list of the parameters for the PF525. You can set many other
parameters
to make this application successful.
Table 4 - Parameter Settings
05
CR30
020100 03 04
A1 15 20 2116
06
18A2
07
19
08 10 11
12 13 14
09
17
+24V DC
Gate control
power supply
Gate control
circuit
M
4 Gnd
S1
S2
1 Stop
L1 L2 L3
PowerFlex
525
2 Start
RTS
UWV
24V DC Com
1
2
6
5
3
7
3
Pink
Receiver
Brown
Brown
Transmitter
Grey
Blue
Green
Blue
11
12
21
22
Parameter Name Value Unit/Description
P042 Decel Time 1 Seconds
P045 Stop Mode 0 Stop and Clear Fault
P046 Start Source 2 Digital Input Terminal Block
P047 Speed Reference 1 1 Drive Pot
T081 Relay 2 2 Motor Running
Motor is receiving power from the drive.
T105 Safety Fault En 0 Fault Enable