Chapter 5
Module Configuration Attributes
484 Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
The purpose of Demo Mode is to allow demonstration of products in
non-industrial environments. It is not intended for use in real motion
applications.
Converter Overtemperature User Limit
Usage Access T Data Type Default Min Max Semantics of Values
Optional - BD Set
REAL 0 0
Degrees Celsius (°C)
This attribute sets the user limit for the Converter Overtemperature UL
exception.
Converter Thermal Overload User Limit
Usage Access T Data Type Default Min Max Semantics of Values
Optional - BD Set
REAL 100 0
% Converter Rated
This attribute sets the user limit for the Converter Thermal Overload UL
exception.
Converter Ground Current User Limit
Usage Access T Data Type Default Min Max Semantics of Values
Optional - BD Set
REAL 100 0
% Factory Limit
This attribute sets the user limit for the Converter Ground Current UL
exception.
Bus Regulator Overtemperature User Limit
Usage Access T Data Type Default Min Max Semantics of Values
Optional - BD Set
REAL 0 0
Degrees Celsius (°C)
This attribute sets the user limit for the Bus Regulator Overtemperature UL
exception.