Publication 1762-RM001C-EN-P
Using High-Speed Outputs 6-3
8. The PTO instruction is DONE.
While the PTO instruction is being executed, status bits and information
are updated as the main controller continues to operate. Because the PTO
instruction is actually being executed by a parallel system, status bits and
other information are updated each time the PTO instruction is scanned
while it is running. This provides the control program access to PTO
status while it is running.
The charts in the following examples illustrate the typical timing
sequence/behavior of a PTO instruction. The stages listed in each chart
have nothing to do with controller scan time. They simply illustrate a
sequence of events. In actuality, the controller may have hundreds or
thousands of scans within each of the stages illustrated in the examples.
Conditions Required to Start the PTO
The following conditions must exist to start the PTO:
The PTO instruction must be in an idle state.
For idle state behavior, all of the following conditions must be met:
Jog Pulse (JP) bit must be off
Jog Continuous (JC) bit must be off
Enable Hard Stop (EH) bit must be off
Normal Operation (NS) bit must be off
The output cannot be forced
The rung it is on must transition from a False state (0) to a True state
(1).
NOTE
PTO status is only as fresh as the scan time of the
controller. Worst case latency is the same as the maximum
scan of the controller. This condition can be minimized by
placing a PTO instruction in the STI (selectable timed
interrupt) file, or by adding PTO instructions to your
program to increase how often a PTO instruction is
scanned.

Table of Contents

Other manuals for Allen-Bradley micrologix 1500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley micrologix 1500 and is the answer not in the manual?

Allen-Bradley micrologix 1500 Specifications

General IconGeneral
Processor Type16-bit
Programming LanguageLadder Logic
MountingDIN rail or panel mount
Programming SoftwareRSLogix 500
Communication PortsRS-232
Power Supply24V DC
Operating Temperature0°C to 55°C (32°F to 131°F)
Controller TypeProgrammable Logic Controller (PLC)

Related product manuals