108 Rockwell Automation Publication 2711R-UM001E-EN-E - January 2017
Chapter 8 Troubleshoot the System
Alert 2068 Only one Trend with data logging is allow Make sure the application only has one Trend with
data logging.
Alert 2069 Landscape Orientation. Confirm Restart? Select No to restart later.
Alert 2070 Portrait Orientation. Confirm Restart? Select No to restart later.
Alert 2071 Application was designed for a different
Orientation and may not appear or operate as
intended. Continue?
Press Yes to continue, or No to cancel. Then change
the orientation of the application in Connected
Components Workbench software to match the
terminal and try again.
Alert 2072 Application was designed for a different Platform
type and Orientation, and may not appear or
operate as intended. Continue?
Press Yes to continue, or No to cancel. Then change
the catalog of the application in Connected
Components Workbench software to match the
terminal and try again.
Alert 2073 Non-validated application is not supported for
CompactLogix controller. Please validate before
loading
Validate the application and correct any validation
errors, save the application, then try again.
Alert 2074 Terminal encountered an exception and will
reboot
This message is for informational purposes. No
corrective action needed.
Alert 2075 Application will be unloaded. Confirm (Y/N)? Press Yes to unload the application.
Alert 2076 This application does not have at least one Goto
Config button. Set as Startup Application?
Press Yes to continue setting the application as a
startup application, or No to cancel. Edit the
application and make sure there is at least one Goto
Config button.
Alert 2077 Controller Settings cannot be changed for running
application.
Stop the application and try again.
Alert 2078 Controller address cannot conflict with PV800
Station Address.
Make sure the controller address is different from
the PanelView terminal 800 station address.
Alert 2079 CompactLogix controller based application must
contain valid path.
Make sure a valid path exists and try again.
Alert 2080 Invalid View-Only password. Password should not
contain any special character.
Make sure the View-Only password does not
contain any special characters.
Alert 2081 Old password does not match with terminal. Make sure the correct password is entered in the
Old Password field.
Alert 2082 VNC Server error. Restart the terminal and try again.
Alert 2083 Controller address cannot be larger than PV800
Max Node('31').
Make sure the address of the controller is smaller
than the maximum node of PanelView 800 (’31’).
Alert 2084 Password cannot be empty. Please enter valid password.
Alert 2085 Enable Ethernet port. Confirm Restart? Press Yes to restart the terminal.
Alert 2086 Disable Ethernet port. Confirm Restart? Press Yes to restart the terminal.
Alert 2087 Enable Serial port. Confirm Restart? Press Yes to restart the terminal.
Alert 2088 Disable Serial port. Confirm Restart? Press Yes to restart the terminal.
Alert 2089 Cannot disable both communication port. Make sure at least one communication port is
enabled.
PanelView 800 Terminal Alerts
Category ID Description Corrective Action