Gas Requirements
68
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Altitude Burner Orifice New Rate
Model Gas feet (meters) No.
inches
( mm) Quantity Part No.
Btu/hr.*
(Mj/hr.)
2,001-4,000
( 610-1,220)
38 0.1015 (2.6) M411376 82,800
(87.35)
4001-6000
(1,221-1,830)
39 0.0955 (2.5) M401007 75,600
(79.76)
6,001-8,000
( 1,831-2440)
41 0.0960 (2.4) M401015 68,400
(72.16)
L.P. Gas
8,001-10,000
( 2,441-3,050)
42 0.0935 (2.4) M403017 61,200
(64.57)
2,001-4,000
( 610-1,220)
15 0.1800 (4.6) M411511 183,000
(193.07)
4,001-6,000
( 1,221-1,830)
17 0.1730 (4.4) M411374 168,400
(177.66)
6,001-8,000
( 1,831-2,440)
18 0.1695 (4.3) M402988 155,000
(163.53)
Natural
Gas
8,001-10,000
( 2,441-3,050)
20 0.1610 (4.1) M401002 142,600
(150.44)
2,001-4,000
( 610-1,220)
36 0.1065 (2.7) M402487 183,000
(193.07)
4,001-6,000
( 1,221-1,830)
37 0.1040 (2.6) M411375 168,400
(177.66)
6,001-8,000
( 1,831-2,440)
38 0.1015 (2.6) M411376 155,000
(163.53)
T45
Series
L.P. Gas
8,001-10,000
( 2,441-3,050)
40 0.0980 (2.5)
2
M406361 142,600
(150.44)
055
Series
Natural
Gas
2,001-4,000
( 610-1,220)
10 0.1929 (4.9) 1 M402994 104,360
(110.1)