EasyManua.ls Logo

Alliance Laundry Systems HTT45N - Page 68

Alliance Laundry Systems HTT45N
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas Requirements
68
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Altitude Burner Orifice New Rate
Model Gas feet (meters) No.
inches
( mm) Quantity Part No.
Btu/hr.*
(Mj/hr.)
2,001-4,000
( 610-1,220)
38 0.1015 (2.6) M411376 82,800
(87.35)
4001-6000
(1,221-1,830)
39 0.0955 (2.5) M401007 75,600
(79.76)
6,001-8,000
( 1,831-2440)
41 0.0960 (2.4) M401015 68,400
(72.16)
L.P. Gas
8,001-10,000
( 2,441-3,050)
42 0.0935 (2.4) M403017 61,200
(64.57)
2,001-4,000
( 610-1,220)
15 0.1800 (4.6) M411511 183,000
(193.07)
4,001-6,000
( 1,221-1,830)
17 0.1730 (4.4) M411374 168,400
(177.66)
6,001-8,000
( 1,831-2,440)
18 0.1695 (4.3) M402988 155,000
(163.53)
Natural
Gas
8,001-10,000
( 2,441-3,050)
20 0.1610 (4.1) M401002 142,600
(150.44)
2,001-4,000
( 610-1,220)
36 0.1065 (2.7) M402487 183,000
(193.07)
4,001-6,000
( 1,221-1,830)
37 0.1040 (2.6) M411375 168,400
(177.66)
6,001-8,000
( 1,831-2,440)
38 0.1015 (2.6) M411376 155,000
(163.53)
T45
Series
L.P. Gas
8,001-10,000
( 2,441-3,050)
40 0.0980 (2.5)
2
M406361 142,600
(150.44)
055
Series
Natural
Gas
2,001-4,000
( 610-1,220)
10 0.1929 (4.9) 1 M402994 104,360
(110.1)

Table of Contents

Other manuals for Alliance Laundry Systems HTT45N

Related product manuals