Installation/Operation/Maintenance
Tumble Dryers
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458301ENR7
January 2014

Table of Contents

Other manuals for Alliance Laundry Systems ST055N

Questions and Answers

  • B
    Benjamin SotoAug 4, 2025
    What to do if Alliance Laundry Systems Dryer has spark but no flame?
    • M
      Michael CastilloAug 4, 2025
      If your Alliance Laundry Systems Dryer has a spark but no flame, first ensure the gas is on. Also, check for 24 VAC at the gas valve. If the issue persists, there might be a problem with the control; in this case check the voltage between the gas valve terminal MV and GND on the control.
  • J
    John AlvarezAug 8, 2025
    Why Alliance Laundry Systems ST055N Dryer valve is on but there is no spark during TFI?
    • J
      Janet SmithAug 8, 2025
      If the valve is on but there's no spark during TFI in your Alliance Laundry Systems Dryer, it could be due to a shorted electrode. Another possible cause is an incorrect spark gap; ensure it's set to .094-.156 inch. Also, inspect the high voltage cable for faults or poor connections. Finally, control failure can cause this issue.
  • J
    Justin PerezAug 13, 2025
    What to do if Alliance Laundry Systems ST055N flame is okay during TFI, but no flame sense after TFI?
    • L
      Laura McmahonAug 13, 2025
      If the flame is okay during TFI but there's no flame sense after TFI in your Alliance Laundry Systems Dryer, check the electrode position and cleanliness. Also, inspect the high voltage wire. Poor grounding at the burner or a poor flame (check flame current) can also cause this issue.
  • R
    Rick MillerAug 17, 2025
    How to fix reset failure on Alliance Laundry Systems ST055N?
    • S
      Shannon EwingAug 17, 2025
      If you're experiencing a reset failure on your Alliance Laundry Systems Dryer, it might be because the reset switch was pressed too long; try resetting again. Another possibility is that the reset switch is shorted, in which case you should replace the switch.
  • J
    Julie LinAug 21, 2025
    What to do if Alliance Laundry Systems Dryer thermostat is on, but there is no spark or valve?
    • A
      Angela WilliamsAug 21, 2025
      If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, first ensure the cable connects to the control and electrode, and that voltage is present at the gas valve. If the issue persists, the control might be bad; check the red LED for a steady on or flashing codes.
  • A
    Ashley GreenAug 26, 2025
    How to reset Alliance Laundry Systems ST055N Dryer control in lockout mode?
    • D
      Dillon JohnsonAug 26, 2025
      If the control in your Alliance Laundry Systems Dryer is in lockout mode, a manual reset is needed. Reset it by pushing the red lockout button or use the front end control.
  • H
    harrisseanAug 30, 2025
    What to do if the Alliance Laundry Systems Dryer control is in lockout mode?
    • S
      Sarah SmithAug 30, 2025
      If the control panel on your Alliance Laundry Systems Dryer is in lockout mode, you will need to manually reset it. You can do this by pushing the red lockout button or using the front end control.

Summary

Front Matter

Important Safety Instructions

Crucial safety guidelines for safe operation and maintenance.

Introduction

Model Identification

Details on identifying specific tumble dryer models and their configurations.

Contact Information

Provides contact details for service, support, and parts.

Safety Information

Safety Information

General safety statements and definitions of hazard symbols (Danger, Warning, Caution).

Important Safety Instructions

Core safety precautions to minimize risks of fire, shock, injury, or death.

Specifications and Dimensions

Specifications and Dimensions

Technical data including weight, dimensions, airflow, and power ratings.

Cabinet Dimensions - 025, 030, 035 and 055 Series

Physical dimensions for dryer series 025, 030, 035, and 055.

Exhaust Outlet Locations - 025, 030, 035 and 055 Series

Specifies exhaust outlet locations and diameters for 025-055 series.

Gas Connection Locations - 025, 030, 035 and 055 Series

Details gas connection points for 025-055 series dryers.

Installation

Pre-Installation Inspection

Steps for inspecting the unit and its packaging before installation.

Location Requirements

Guidelines for choosing a suitable and safe installation location.

Position and Level the Tumble Dryer

Instructions for properly placing and leveling the dryer.

Electrical Requirements

Outlines power supply, wiring, and grounding requirements for safe operation.

Gas Requirements

Gas Requirements

Essential information for connecting and operating the dryer with gas.

Gas Supply Pipe Sizing and Looping

Guidelines for sizing and installing gas supply piping for optimal pressure.

High Altitude Burner Orifice Sizing

Instructions for adjusting burner orifices based on altitude for proper combustion.

Electrical Requirements

Electrical Requirements

Detailed requirements for electrical connections, grounding, and wiring.

Grounding Instructions

Critical steps for ensuring proper electrical grounding for safety.

To Connect Electrical Service To The Tumble Dryer

Step-by-step guide for making the final electrical service connection.

Electrical Specifications

Tables detailing voltage, amperage, breaker, and wire size requirements.

Steam Requirements

Steam Requirements

Critical information regarding steam pressure and pipe sizing for operation.

Piping Recommendations

Guidelines for steam supply and return line installation and support.

Installing Steam Trap and Making Condensate Return Connections

Steps for properly installing steam traps and condensate lines.

Single Drop Timer

Power-Up Mode

Describes the initial state of the control when power is applied.

Ready Mode

The state where the control awaits a coin or vend satisfaction.

Setting Dry Time Dipswitches

How to adjust drying times using dipswitches on the control.

Dipswitch Settings

Tables detailing dipswitch configurations for various time settings.

Operating Instructions

Operating Instructions

General guidelines for operating the tumble dryer.

Clean Lint Screen;Compartment

Instructions for daily cleaning of the lint screen and compartment.

Load Laundry

Guidance on properly loading the dryer with laundry.

Dual Digital Timer Control

Operating instructions for Dual Digital Timer (QT, RQ) controls.

Diagnostic Microprocessor Control

General Operation

Overview of how the DMP control manages drying and cooling cycles.

Programming

Steps for programming custom cycles and settings on the DMP control.

Reversing Operation

Details on setting up and adjusting cylinder reversing functions.

Adjustments

Gas Burner Air Shutter

How to adjust the air shutter for optimal combustion and efficiency.

Airflow Switch

Information on the airflow switch and its importance for safety.

Loading Door Switch

Instructions for adjusting the door switch for proper operation.

Door Strike

How to adjust the door strike for proper door closure tension.

Maintenance

Daily

Routine daily checks and cleaning procedures for the dryer.

Monthly

Monthly maintenance tasks to ensure proper airflow and prevent overheating.

Fire Suppression System Maintenance Test

Procedure for testing the fire suppression system every three months.

Before You Call for Service

Troubleshooting Guide

Troubleshooting guide for common starting, heating, and drying issues.

Removing Tumble Dryer from Service

Steps for Removal from Service

Steps for safely disconnecting and removing the dryer from service.

Disposal of Unit

Appliance Disposal Guidelines

Information on proper disposal of the appliance according to WEEE directive.

Alliance Laundry Systems ST055N Specifications

General IconGeneral
BrandAlliance Laundry Systems
ModelST055N
CategoryDryer
TypeTumble Dryer
Voltage208-240V
Amperage30A
Heating MethodElectric
Capacity55 lb

Related product manuals