Installation/Operation/Maintenance
Tumble Dryers
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458301ENR7
January 2014

Table of Contents

Other manuals for Alliance Laundry Systems STT45N

Questions and Answers

  • K
    kvillanuevaAug 3, 2025
    What to do if Alliance Laundry Systems STT45N has spark but no flame?
    • A
      Alexandra KempAug 4, 2025
      If your Alliance Laundry Systems Dryer has a spark but no flame, first ensure the gas is on. Also, check for 24 VAC at the gas valve. If the issue persists, there might be a problem with the control; in this case check the voltage between the gas valve terminal MV and GND on the control.
  • C
    Cheryl ChapmanAug 7, 2025
    Why Alliance Laundry Systems Dryer valve is on but there is no spark during TFI?
    • A
      Alicia WrightAug 7, 2025
      If the valve is on but there's no spark during TFI in your Alliance Laundry Systems Dryer, it could be due to a shorted electrode. Another possible cause is an incorrect spark gap; ensure it's set to .094-.156 inch. Also, inspect the high voltage cable for faults or poor connections. Finally, control failure can cause this issue.
  • K
    Kayla OwensAug 11, 2025
    What to do if Alliance Laundry Systems Dryer flame is okay during TFI, but no flame sense after TFI?
    • S
      sanchezcatherineAug 12, 2025
      If the flame is okay during TFI but there's no flame sense after TFI in your Alliance Laundry Systems Dryer, check the electrode position and cleanliness. Also, inspect the high voltage wire. Poor grounding at the burner or a poor flame (check flame current) can also cause this issue.
  • B
    belljodiAug 16, 2025
    How to fix reset failure on Alliance Laundry Systems STT45N?
    • S
      Sharon Wilcox MDAug 16, 2025
      If you're experiencing a reset failure on your Alliance Laundry Systems Dryer, it might be because the reset switch was pressed too long; try resetting again. Another possibility is that the reset switch is shorted, in which case you should replace the switch.
  • T
    Tina GriffithAug 20, 2025
    What to do if Alliance Laundry Systems STT45N Dryer thermostat is on, but there is no spark or valve?
    • K
      Kevin GrimesAug 20, 2025
      If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, first ensure the cable connects to the control and electrode, and that voltage is present at the gas valve. If the issue persists, the control might be bad; check the red LED for a steady on or flashing codes.
  • P
    pearsonamandaAug 25, 2025
    How to reset Alliance Laundry Systems STT45N control in lockout mode?
    • K
      Kelly LopezAug 25, 2025
      If the control in your Alliance Laundry Systems Dryer is in lockout mode, a manual reset is needed. Reset it by pushing the red lockout button or use the front end control.
  • J
    Joseph StoneAug 29, 2025
    What to do if the Alliance Laundry Systems STT45N Dryer control is in lockout mode?
    • T
      Taylor FlowersAug 29, 2025
      If the control panel on your Alliance Laundry Systems Dryer is in lockout mode, you will need to manually reset it. You can do this by pushing the red lockout button or using the front end control.

Summary

Front Matter

Installation Codes and Safety

General installation compliance with codes and safety warnings.

Introduction - Model Identification

Safety Information

Safety Definitions and Instructions

Defines safety terms (DANGER, WARNING, CAUTION) and gives important safety instructions.

Specifications and Dimensions - General

Specifications - Connection and Outlet Locations

Installation - Pre-Installation and Location

Installation - Leveling and Support

Installation - Utilities and Safety Systems

Installation - Electrical and Door

Installation - CE Gas Drying Specifics

Gas Requirements - General

Gas Requirements - Conversion and Orifice Data

Steam Requirements - Pressure and Piping

Steam Requirements - Trap and Condensate

Single Drop Timer Operation

Timer Modes and Settings

Explains the various modes of operation for the single drop timer control.

Single Drop Timer - Dipswitch Configuration

Single Drop Timer - Programming Test Cycles

Operating Instructions - General

Operation and Safety Basics

Basic safety precautions and operational steps, including cleaning the lint screen.

Operating Instructions - Controls and Loading

DX4 Control Operation

Coin and OPL Control Procedures

Instructions for operating DX4 coin and OPL control models, including cycle selection.

Diagnostic Microprocessor Control - Operation

Ignition Control - Operation and Troubleshooting

Fault Conditions and Troubleshooting

Details fault conditions and provides a guide to diagnose common ignition control issues.

Adjustments - Burner and Airflow

Adjustments - Door Mechanisms

Maintenance - Daily and Monthly Tasks

Maintenance - Periodic Tasks

Fire Suppression System Maintenance Test

Before You Call for Service

Removing Tumble Dryer from Service

Disposal of Unit

Alliance Laundry Systems STT45N Specifications

General IconGeneral
BrandAlliance Laundry Systems
ModelSTT45N
CategoryDryer
LanguageEnglish

Related product manuals