November 2016
Service

Table of Contents

Questions and Answers

  • Y
    Yvette MartinAug 16, 2025
    Why won't the burner ignite on my Alliance Laundry Systems ST0300DRG?
    • E
      Ebony HowardAug 16, 2025
      If the burner on your Alliance Laundry Systems Dryer isn't igniting, several issues could be the cause. Check for blown fuses or a tripped circuit breaker, ensure the gas shut-off valve is open, and verify sufficient gas supply and pressure. Also, inspect for lint buildup, proper ductwork, and adequate make-up air. The drying selector should not be set to the “Cool Down” portion of the cycle. Other potential causes include incorrect orifices, wiring issues, a faulty airflow switch, inoperative cabinet thermostat, or problems with the IEI control or motor switch. The lint drawer/panel must be closed properly. Refer to the Installation Instructions for exhaust system and make-up air requirements.
  • W
    William MoranAug 19, 2025
    Why does the burner ignite and go out repeatedly on my Alliance Laundry Systems ST0300DRG?
    • R
      Robert ShawAug 19, 2025
      If the burner in your Alliance Laundry Systems Dryer ignites and then goes out repeatedly, it could be due to insufficient gas pressure, an inoperative cabinet thermostat, or an improper or inadequate exhaust system. Improper orifices, broken, loose, or incorrect wiring, excessive igniter to burner clearance, or inadequate make-up air could also be the cause. Refer to the Installation Instructions for exhaust systems and make-up air requirements.
  • M
    Michelle PowellAug 22, 2025
    What to do if burners are not burning properly on Alliance Laundry Systems ST0300DRG Dryer?
    • H
      holtdeniseAug 22, 2025
      If the burners on your Alliance Laundry Systems Dryer are not burning properly, check for dirt in the burners and clean them if necessary. Ensure the gas pressure is correct according to the rating plate and that the correct orifices are installed. A restricted or blocked exhaust duct, a malfunctioning airflow switch, or inadequate make-up air could also be the cause. Refer to the Installation Instructions for make-up air requirements.
  • E
    Eric GregoryAug 26, 2025
    What causes the burner to not shut off on Alliance Laundry Systems Dryer?
    • P
      Paula MillerAug 26, 2025
      If the burner on your Alliance Laundry Systems Dryer does not shut off, it could be due to impurities on the gas valve seat, preventing the valve from closing, in which case the gas valve should be replaced. Incorrect wiring could also be a cause. Refer to the wiring diagram.
  • B
    Beth RiosAug 28, 2025
    Why don't my clothes dry in my Alliance Laundry Systems Dryer?
    • B
      Brett HubbardAug 28, 2025
      Several factors can prevent your Alliance Laundry Systems Dryer from properly drying clothes. Ensure you're allocating enough heating time, and that the drying selector is appropriately set. Reduce the load size if it's too large (the maximum load is 25 lb dry weight for a 25 lb dryer). Also, make sure there isn't too much water in the clothes before drying. Check for a blocked exhaust duct or a clogged lint screen, and ensure the exhaust damper isn't binding. Other potential issues include an inoperative thermistor, burner problems, incorrect voltage, or inadequate make-up air. Refer to the Installation Instructions for exhaust system and electrical requirements.
  • S
    Sarah ThorntonAug 31, 2025
    Why does the motor overload protector cycle repeatedly on my Alliance Laundry Systems Dryer?
    • J
      Jeremy CastroAug 31, 2025
      If the motor overload protector in your Alliance Laundry Systems Dryer cycles repeatedly, it could be due to several reasons. The clothes load might be too large, or the cylinder could be binding. Check for correct voltage and adequate wiring, and ensure there's sufficient make-up air. Lint buildup around the dryer and motors can also cause this issue, as can broken, loose, or incorrect wiring. Refer to the Installation Instructions for electrical and make-up air requirements.
  • S
    Shannon BooneSep 3, 2025
    Why is my Alliance Laundry Systems ST0300DRG Dryer overheating?
    • M
      Michael GonzalezSep 3, 2025
      If your Alliance Laundry Systems Dryer is overheating, it could be due to several factors. Ensure the correct main burner orifices are installed and that the gas pressure is properly adjusted. Check for lint buildup and ensure the exhaust system is not restricted or inadequate. Also, make sure there is adequate make-up air and that the exhaust damper is not binding. An inoperative thermistor sensor could also be the cause. Refer to the Installation Instructions for make-up air and exhaust system requirements.
  • B
    Bryan BakerSep 6, 2025
    What to do if motor runs but cylinder does not turn in Alliance Laundry Systems Dryer?
    • K
      Kaitlyn JohnsonSep 6, 2025
      If the motor in your Alliance Laundry Systems Dryer runs but the cylinder doesn't turn, the cylinder belt may be broken and needs replacement. Another possible cause is that the cylinder is binding, so check the cylinder for any obstructions.
  • S
    Samuel BarnettSep 9, 2025
    Why does the motor not stop in my Alliance Laundry Systems ST0300DRG?
    • K
      Katrina KhanSep 9, 2025
      If the motor in your Alliance Laundry Systems Dryer does not stop, it could be due to an inoperative door switch or lint drawer switch, which should be tested and replaced if faulty. An inoperative coin drop or a malfunctioning electronic control could also be the cause. Incorrect wiring may also be responsible. Refer to the wiring diagram.
  • T
    Tonya RochaSep 12, 2025
    What to do if cylinder door opens during operation of Alliance Laundry Systems ST0300DRG?
    • M
      Michelle HowardSep 12, 2025
      If the cylinder door on your Alliance Laundry Systems Dryer opens during operation, it may be due to the dryer being improperly leveled. Also, an excessive load in the dryer can cause this issue; remove part of the load and restart the dryer.

Summary

Section 1 Safety Information

Section 3 Troubleshooting

Dryer Does Not Start

Addresses potential causes and solutions when the tumble dryer fails to start.

Motor Does Not Start

Troubleshooting steps for a motor that does not engage or operate.

Burner Does Not Ignite

Troubleshooting steps for when the burner fails to ignite properly.

Clothes Do Not Dry

Common causes and fixes for clothes not drying effectively in the tumbler.

Tumble Dryer Overheating

Diagnoses and resolves overheating issues within the tumble dryer.

Section 4 Grounding

Grounding Instructions

Essential guidelines and procedures for proper electrical grounding of the dryer.

Section 5 Service Procedures

Complete Gas Valve Assembly

Procedures for removing and replacing the entire gas valve assembly.

Section 6 Adjustments

Alliance Laundry Systems ST0300DRG Specifications

General IconGeneral
BrandAlliance Laundry Systems
ModelST0300DRG
CategoryDryer
TypeTumble Dryer
Capacity30 lb
Heat SourceGas
Reversing ActionYes
Door SwingReversible
Phase1-Phase

Related product manuals