EasyManua.ls Logo

Alliance Laundry Systems ST030E - User Manual

Alliance Laundry Systems ST030E
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation/Operation/Maintenance
Tumble Dryers
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458301ENR7
January 2014

Table of Contents

Other manuals for Alliance Laundry Systems ST030E

Questions and Answers

  • P
    Patricia WilliamsAug 4, 2025
    What to do if Alliance Laundry Systems ST030E has spark but no flame?
    • J
      jennifer56Aug 4, 2025
      If your Alliance Laundry Systems Dryer has a spark but no flame, first ensure the gas is on. Also, check for 24 VAC at the gas valve. If the issue persists, there might be a problem with the control; in this case check the voltage between the gas valve terminal MV and GND on the control.
  • B
    blake88Aug 8, 2025
    Why Alliance Laundry Systems ST030E Dryer valve is on but there is no spark during TFI?
    • K
      Kevin PittmanAug 8, 2025
      If the valve is on but there's no spark during TFI in your Alliance Laundry Systems Dryer, it could be due to a shorted electrode. Another possible cause is an incorrect spark gap; ensure it's set to .094-.156 inch. Also, inspect the high voltage cable for faults or poor connections. Finally, control failure can cause this issue.
  • R
    robinsondonAug 12, 2025
    What to do if Alliance Laundry Systems ST030E flame is okay during TFI, but no flame sense after TFI?
    • L
      lauren31Aug 13, 2025
      If the flame is okay during TFI but there's no flame sense after TFI in your Alliance Laundry Systems Dryer, check the electrode position and cleanliness. Also, inspect the high voltage wire. Poor grounding at the burner or a poor flame (check flame current) can also cause this issue.
  • D
    Danielle KingAug 16, 2025
    How to fix reset failure on Alliance Laundry Systems ST030E?
    • J
      Jason LuceroAug 16, 2025
      If you're experiencing a reset failure on your Alliance Laundry Systems Dryer, it might be because the reset switch was pressed too long; try resetting again. Another possibility is that the reset switch is shorted, in which case you should replace the switch.
  • L
    louis13Aug 21, 2025
    What to do if Alliance Laundry Systems ST030E thermostat is on, but there is no spark or valve?
    • P
      pmarshallAug 21, 2025
      If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, first ensure the cable connects to the control and electrode, and that voltage is present at the gas valve. If the issue persists, the control might be bad; check the red LED for a steady on or flashing codes.
  • C
    Charles WilliamsAug 26, 2025
    How to reset Alliance Laundry Systems ST030E Dryer control in lockout mode?
    • R
      Ryan EstesAug 26, 2025
      If the control in your Alliance Laundry Systems Dryer is in lockout mode, a manual reset is needed. Reset it by pushing the red lockout button or use the front end control.
  • D
    Daniel PorterAug 30, 2025
    What to do if the Alliance Laundry Systems Dryer control is in lockout mode?
    • L
      Lori CarrollAug 30, 2025
      If the control panel on your Alliance Laundry Systems Dryer is in lockout mode, you will need to manually reset it. You can do this by pushing the red lockout button or using the front end control.

Summary

Front Matter

Installation Compliance

Installation must conform with local codes and national standards for safety.

Introduction

Model Identification

Details the various model numbers and their corresponding gas, steam, and electric configurations.

Safety Information

General Safety Precautions

Defines hazard symbols and precautionary statements for safe operation and maintenance.

Important Safety Instructions

Key precautions to reduce risk of fire, electric shock, injury, or death during use.

Specifications and Dimensions

Product Specifications Overview

Details general specifications including weight, packaging, dimensions, motors, and airflow for various models.

Cabinet Dimensions

Provides detailed cabinet dimensions for 025, 030, 035, 055 and T30, T45 series models.

Exhaust Outlet Locations

Illustrates exhaust outlet locations and dimensions for 025, 030, 035, 055 and T30, T45 series.

Gas Connection Locations

Details gas connection points and dimensions for various series and regions.

Electrical Connection Locations

Specifies electrical connection points and dimensions for different model series and heat sources.

Steam Connection Locations

Provides steam connection locations and dimensions for 025, 030, 035 and T30 series models.

Installation

Pre-Installation Inspection

Steps for inspecting the unit upon delivery and ensuring readiness for installation.

Location Requirements

Guidelines for selecting a suitable installation location, considering floor, environment, and clearances.

Exhaust Requirements

Make-Up Air Requirements

Specifies the required make-up air opening size for each model to ensure proper ventilation.

Venting Guidelines

Recommendations and warnings for proper exhaust ducting, including static pressure and lint accumulation.

Gas Requirements

Gas Pressure and Supply

Details natural and LP gas pressure requirements and necessary supply components.

Gas Conversion and Orifice Sizing

Provides guidance on selecting and changing burner orifices for proper gas operation at different altitudes.

Electrical Requirements

Wiring and System Connections

Information on wiring diagrams, central pay system connections, and wire color codes.

Grounding Instructions

Essential steps for proper electrical grounding to prevent shock hazards.

Service and Ground Locations

Identifies ground and terminal block locations for various models and heat sources.

Connecting Electrical Service and Voltage Configuration

Procedure for connecting electrical service and configuring for different voltages.

Steam Requirements

Steam Pressure and Piping

Specifies required steam pressure, pipe sizing, and general piping recommendations.

Steam Trap and Condensate Return

Instructions for installing steam traps and connecting condensate return lines.

Single Drop Timer

Control Modes Overview

Describes the operational states of the single drop timer control.

Setting Dry Time Dipswitches

Guide to configuring dry time and cool down time using dipswitches on the control.

Resetting Cycle Time

Procedure for resetting the cycle time to zero on specific models.

Operating Instructions

General Operation Warnings

Important warnings regarding drying specific materials to prevent fire and injury.

Emergency Stop Button

Instructions on how to operate the emergency stop button on CE models.

Electronic OPL Micro Control

Control Operation and Settings

Guide for operating the Electronic OPL Micro Control and setting temperatures.

Adjustments

Gas Burner Air Shutter Adjustment

Procedure for adjusting the air shutter for optimal burner combustion and flame intensity.

Maintenance

Daily Maintenance

Routine checks and cleaning tasks to be performed daily for proper operation and safety.

Monthly Maintenance

Tasks to be performed monthly, focusing on exhaust duct and internal cleaning.

Before You Call for Service

Troubleshooting Common Issues

Common troubleshooting steps for issues like won't start, won't heat, or clothes not dry.

Removing Tumble Dryer from Service

Disposal of Unit

Alliance Laundry Systems ST030E Specifications

General IconGeneral
BrandAlliance Laundry Systems
ModelST030E
CategoryDryer
TypeTumble Dryer
Capacity30 lb
Heat SourceElectric
Voltage208-240 V