EasyManua.ls Logo

Alpha ESS T100 - Page 36

Alpha ESS T100
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
______________________________________________________________________
Alpha ESS Co., Ltd.
Page 36 of 45
Your Smart Energy
normally and the
inside temperature
should be between
5 to 40 degree
Lighting
power
supply
Check the
lighting supply;
all the lights
should work
normally
Once
6 months
All the lights should
work normally
Work cloth;
Protective shoes
Emergency
lighting
Check the
emergency
lighting
equipments; all
the lights should
work normally
Once
6 months
All emergency
lights should work
normally after
power supply is
down
Work cloth;
Protective shoes
Firefighting
equipment
Check the
firefighting
equipments; the
equipments
should be on
without any
alarms
Once
6 months
The equipments
should be on
without any alarms
and the pressure of
gas tank should be
normal (by
checking the
indicator needle,
green means OK)
Work cloth;
Protective shoes
Bracket
surface
Check the
brackets for rust
or damage
Once 6
month
No rusting or
damage
Work cloth;
Protective shoes
Bracket
fixing
Check the fixing
of brackets
between
brackets and
ground of the
container
Once 6
months
All bolts are tight
Work cloth;
Protective shoes;
Wrenches
Module
surface
Check the
modules for rust
or damage
Once 6
months
No rusting or
damage
Work cloth;
Protective shoes
Module
fixing
Check the fixing
of modules
between
modules and
brackets
Once 6
months
All bolts on module
are tight
Work cloth;
Protective shoes;
Wrenches;
Insulated gloves
Module
connection
Check the
module serial
Once 6
months
All bolts of copper
bars and cables are
Work cloth;
Protective shoes;