EasyManua.ls Logo

Alpha ESS T100 - Routine Maintenance

Alpha ESS T100
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
______________________________________________________________________
Alpha ESS Co., Ltd.
Page 38 of 45
Your Smart Energy
Routine Maintenance
Item
Equipment
Maintenance
cycle
Training/qualification
requirements
Container
surface
Painting on
rusting
position
Work clothes;
Protective
shoes;
Anticorrosive
paint
6 months
Corresponding color number
Container
inside
cleaning
Work clothes;
Protective
shoes;
Broom; Cloth
6 month
Clean dusts and rubbish
Air
conditioner
Work clothes;
Protective
shoes;
6 months
Visually check if the wiring is
loose;
Turn the fan to check if it is
smooth and if there is
any abnormal noise;
Visually check if the drainage
mouth is blocked
Check the cleanness of the
condenser and clean it
with compressed air
Battery
system
Painting on
brackets
Work clothes;
Protective
shoes;
Anticorrosive
paint
6 months
Corresponding color number
Fixing on
brackets
Work clothes;
Protective
shoes;
Wrench
6 months
Fixing between brackets and
container ground
Grounding
of brackets
Work clothes;
Protective
shoes;
Screwdriver
3 months
Use multimeter to test grounding.
Battery
system
cleaning
Work clothes;
Protective
shoes;
Cloth
6 months
The brackets and modules should
be clean
Painting on
modules
Work clothes;
Protective
shoes;
6 months
Corresponding color number