5Subject to technical amendments without prior notice | 83055800gUK – Translation of the original operating manual | ait-deutschland GmbH
Risk of injury from moving parts
Only switch on the device when the covers and
fanprotectiongrillearetted.
Injuries and environmental damage due to
refrigerant
Thedevicecontainsammable,harmfulandenviron-
mentally dangerous refrigerant. If refrigerant leaks out
of the device, there is a risk of explosion:
1. Switcho󰀨thedevice.
2. Notify an authorised after sales service.
3. Keep away from sources of ignition.
2.5 Disposal
Environmentally hazardous media
Improper disposal of environmentally hazardous me-
dia(refrigerant)willdamagetheenvironment:
Collect media safely.
Dispose of the media in an environmentally sound
manner in accordance with the local regulations.
2.6 Avoid material damage
The ambient air at the heat pump’s installation site and
the air drawn in as a heat source must not contain any
corrosive components!
Constituents such as
Ammonia
Sulphur
Chlorine
Salt
Sewagegases,uegases
can cause damage to the heat pump, which can even
result in the complete failure/total loss of the heat pump.
Decommissioning/draining the heating
If the system/heat pump is decommissioned or drained
after already being lled, it must be ensured that
the condenser and any heat exchangers have been
drained completely in the event of freezing tempera-
tures. Residual water in heat exchangers and con-
densers can result in damage to the components.
Completely drain the system and the condenser,
and open vent valves.
Blow them clear with compressed air, if required.
Improper action
Requirements for minimum scale and corrosion dam-
age in hot water heating systems:
Professional planning and commissioning
Closed system with regard to corrosion
Integration of an adequately dimensioned pres-
sure maintenance
Useofdemineralisedheatingwater(VEwater)or
water corresponding to the VDI 2035 norm
Regular servicing and maintenance
If a system is not planned, commissioned and operated
in accordance with the given requirements, there is a
risk of the following damage and malfunctions:
Malfunctions and failure of components, e.g. pumps,
valves
Internal and external leaks, e.g. at heat exchangers
Reduction in cross-section and blockages in com-
ponents, e.g. heat exchangers, pipes, pumps
Material fatigue
Gas bubbleand gascushiondevelopment(cavi-
tation)
Negativee󰀨ectonheattransfer,e.g.duetoforma-
tion of deposits, and associated noises, e.g. boiling
noises,ownoises
Observe the information in this operation manual
for all work on and with the device.
Unsuitablequalityofthewaterforllingand
replenishing the heating circuit
Thee󰀩ciencyofthesystemandtheservicelifeofthe
heat generator and the heating components depend
decisively on the quality of the heating water.
Ifthesystemislledwithuntreateddrinkingwater,cal-
cium deposits will form as scale. Limescale deposits
accumulate on the heat transfer surfaces of the heat-
ing.E󰀩ciencyisreducedandenergycostsincrease.In
extreme cases, the heat exchangers will be damaged.
Fill the system with deionised heating water
(VEwater)orwithwatercorrespondingtotheVDI
2035normonly(low-saltoperationofthesystem).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec LWDV Series and is the answer not in the manual?

Alpha-InnoTec LWDV Series Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLWDV Series
CategoryHeat Pump
LanguageEnglish

Related product manuals