Cooling
Cooling is integrated in type K units. Type H units can
beretrottedwiththe“Coolingpackage”accessories.
The following options are possible for units with
cooling function ( operating manual of the heating
and heat pump controller):
● Passive cooling (without compressor)
● Control of the cooling function via the heating and
heat pump controller
● Switching between heating and cooling mode;
automatically with expansion board (accessories)
Networkconnectiononthecontrolunit
The control unit can be connected to a computer or
network via a network cable. The heating and heat
pump controller can then be controlled from the
computerorfromthenetwork.
4 Operation and care
NOTE
The unit is operated via the control unit
of the heating and heat pump controller
( operating manual of the heating and heat
pump controller).
4.1 Energy and environmentally
aware operation
The generally accepted requirements for energy-
aware and environmentally-aware operation of a
heating system also apply to use of a brine/water heat
pump. The most important measures include:
● No unnecessarily high ow temperature
● No unnecessarily high domestic hot water
temperature (note and follow local regulations)
● Do not open windows with gap /tilt open
(continuous ventilation), but instead open wide for
a short time (purge ventilation).
4.2 Maintenance
Wipe down the outside of the unit only using a damp
cloth or cloth with mild cleaning product (washing-up
liquid, neutral cleaning product). Do not use any harsh,
abrasive, acid or chlorine-based cleaning products.
5 Delivery, storage,
transport and installation
5.1 Scope of supply
NOTE
On delivery the accessories are enclosed in
twopackagesontheheatingstation.
► Check delivery immediately after receipt for
outwardly visible damage and completeness.
► Notify supplier of any defects immediately.
Theseparatepackincludedcontains:
● Sticker with the unit number for attaching to page
3 of this manual
● Control unit consisting of wall bracket, cover,
control with rear bracket
●
6
-mm anchors with screws (2x each) for wall-
mounting the control unit
● Safety valve, outdoor sensor
● Compression ttings
● Replacement material after dismantling the
module box: Insulation hoses (2x), cable ties (4x),
O-rings (6x)
5.2 Storage
► Where possible do not unpack the unit until
directly before installation.
► Store unit protected against:
–
Moisture/damp
–
Frost
–
Dust and dirt