Chapter 4 Parameter Index
http://www.acdrive-china.com
63
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P0.18
V/F
voltage
value V3
V/F
voltage
value V3
0100.0%
80.0%
× 0112
P0.19
Control
mode
Control
mode
0.0: Magnetic flux
vector
control
0.130.0%:
Manual
torque boost
3004G
B or
below:
4.0%
35R5G
B/37R5
PB or
above:
0.0%
0113
P0.20
Cut-off
point used
for manual
torque
boost
Cut-off
point used
for boost
0.0050.00Hz
16.67Hz
0114
P0.21
Acc time1 Acc time1
0115
P0.22
Dec time1 Dec time1
3132G/3160P or
below:
0.13600s
3160G/3185P or
above :
1.03600s
3022G/
3030P
or
below:
60s
3030G/
3037P
or
over :
20.0s
0116