EasyManua.ls Logo

Alpha ARES 150 Tec - Page 16

Alpha ARES 150 Tec
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Instructions for the installer
Alpha ARES Tec 150 - 350
Example:
ARES Tec 250
Maximum ue ow rate = 408.6 Kg/h
Height of ue = 25 m
Diameter = 250 mm
NOTE:
e diagram above provides rough values only. e
ue must be designed by a qualied professional in
compliance with legislation and technical standard
in force.
Table of maximum ue ow rate
Model
Max ue ow rate (kg/h)
150
245
200 327
250 409
300 490
350 569
FLUE SIZING ACCORDING TO DIN 4705
2
Nominal heat input (kW)
Nominal thermal ow rate (kW) with CO content at 10%
2
d125
a
d400
a
d315
a
d250
a
d200
a
d160
a
d110
a
d75
a
6
7
8
9
10
12
14
16
18
20
30
40
50
60
70
80
90
100
120
140
160
180
200
300
400
500
600
700
800
900
1000
1200
1400
4.4
5.9
6.6
7.4
8
9
10
12
22
30
37
44
52
59
66
74
89
104
119
133
148
222
296
370
444
519
593
668
741
889
1037
3.4
3.9
4.4
5.0
5.6
7
8
9
11
17
22
28
34
39
44
50
56
67
78
89
100
111
167
222
277
333
389
445
555
667
778
0.001
0.002
0.003
0.004
0.005
0.006
0.007
0.008
0.009
0.010
0.015
0.020
0.030
0.035
0.040
0.050
0.060
0.070
0.080
0.090
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.500
0.600
5
0.700
9.0
10.8
12.0
14.4
22
25
29
32
36
54
72
90
108
126
144
180
216
252
288
324
360
540
720
900
1080
1260
1440
1800
2160
2520
6
7
8
9
10
12
14
16
18
20
30
40
50
60
70
80
90
100
120
140
160
180
200
300
400
500
600
700
800
900
1000
1200
1400
8%
6%
kg/skg/h 10%
10 15 20 25 30
5 10 15 20 25 30
Available pressure
Flue ow rate
Flue temperature
40 Pa
40°C
408
250
CO content
0.025
18
10
15
13
501

Related product manuals