Alpine Supply Company 42 Direct Vent Gas Fireplace
SAFETY INFORMATION
Listed: DIRECT VENT GAS FIREPLACE HEATER
Tested to: ANSI Z21.88.2002./CSA2.33a-2002
VENTED GAS FIREPLACE HEATER.
Report No.
3031549 2/02
DO NOT REMOVE THIS LABEL
Serial Number: ALPINE SUPPLY COMPANY ASC 42
PROPANE : Series ASC42-LP
Minimum supply pressure 11” WC
Manifold pressure high 10.0” WC
Manifold pressure low 5.8” WC
Orifice Size # 55 DMS
Minimum input 16,000 BTU/h
Maximum input 23,000 BTU/h
Altitude 2500 – 6500 Ft
NATURAL GAS : Series ASC42-NG
Minimum supply pressure 5” WC
Manifold pressure high 3.5”” WC
Manifold pressure low .8” WC
Orifice Size # 43 DMS
Minimum input 13,400 BTU/h
Maximum input 26,000 BTU/h
Altitude 2500 – 6500 Ft
Model ASC42-LP
Model ASC42-NG
Use Only Simpson Dura-Vent GS System . Use only Simpson vent cap #0991 on vertical applications. This appliance
must be installed in
accordance with the manufacturer’s installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA. This
vented gas fireplace heater is not for use with air filters. # 432-917 Fan Kit may be used.
Electrical supply 120VAC, .62 Amps, 60Hz.
VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUEL.
Alpine Gas Fireplaces
Lehi, Utah
Made in USA
Field Converted
Put Label Here
This appliance must be installed in
accordance with the following minimum
clearances:
1 1/2” to combustibles – Top
1/2” to combustibles – Sides
1/2” to combustibles – Back
0” to combustibles – Bottom
18” Top of stove – Ceiling (Flex Vent)
14” Top of stove – Ceiling (Rigid Vent)
6” to combustible Mantel
( projecting a maximum of 6” )
The Flue requires the following
minimum clearances on Horizontal
Vent:
2” to combustibles – Top
1” to combustibles – Sides
1/2” to combustibles – Bottom
The Flue requires the following
minimum clearances on Vertical Vent:
1 1/2” to combustibles – Vertical
This appliance may be recessed until the
front of the unit is flush with any facing
material.