COMBITHERM GAS INSTALLATION AND MAINTENANCE MANUAL — 6470ML
PG. 22
COMBITHERM® CLEANING & MAINTENANCE
2.6 Monthly Cleaning — GAS
Perform once a month in addition to
the daily oven cleaning procedure.
2.6.1 WATER INTAKE FILTER CLEANING
Monthly cleaning of the filter at the front of the water intake
connection will prevent the water injection system from
becoming blocked.
1. Press the oven power switch to the OFF position.
2. Disconnect the water intake connection located below the oven.
3. Remove the line filter and clean thoroughly.
4. Replace the line filter and
reconnect the water.
5. Press the oven power switch to the ON
position and check to make certain the
water intake connection does not leak.
2.6.2 CLEANING THE DRAIN PIPE
Fats and solids will eventually coagulate in the
drain system, causing blockage. Consequently,
water will back-up into the interior oven
compartment, resulting in an oven that is
inoperable. Monthly cleaning of the oven drain
will prevent the drain from becoming blocked.
1. Press the oven power switch to the OFF position.
2. Locate the drain outlet below the oven and remove the drain plug
with a wrench.
3. Thoroughly dislodge and remove the accumulated deposits through
the drain plug outlet or through the drain opening at the bottom of
the oven interior. Rinse out the open drain with the hand-held hose.
4. Replace the drain plug and tighten securely with a wrench.
5. Press the oven power switch to the ON position and check to make certain
the drain does not leak.
2.6.3 CLEANING THE FLUE OUTLET
Inspect the flue diverter assembly located on the top of the oven on a monthly
basis. Remove accumulated dirt and debris.
KEEP THE OVEN EXHAUST OUTLET CLEAR