1
• Spare Parts Book
870/20008/4
07/18
Operators Manual
GB
10
BELLE
ROLLER STRIKER
4

Questions and Answers

  • L
    lwilsonAug 20, 2025
    How to start Altrad BELLE Trowels if the engine won't start?
    • L
      Leslie PayneAug 20, 2025
      If your Altrad Trowels engine won't start, first ensure the fuel tap is open and the fuel tank is adequately filled. Then switch the engine on and verify that the cut-out switch is in the ON position. Clean and reset the spark plug gap if it's fouled. If the engine is cold, close the choke.
  • M
    Marcus GarrettAug 22, 2025
    What to do if Altrad BELLE are leaving swirls in concrete?
    • A
      Andrew CaldwellAug 22, 2025
      If your Altrad Trowels are leaving swirls in concrete, rolling concrete, or bouncing, inspect the main shaft of the gearbox. Also, check the spider plate for bent trowel arms; replace any that are bent. Ensure the trowel arms are properly adjusted, the blades are of the same measure, and that the blades are not excessively worn.
  • J
    Jason CollinsAug 25, 2025
    What to do if my Altrad Construction Equipment machine stops suddenly?
    • H
      hernandezalexAug 25, 2025
      If your Altrad Construction Equipment machine stops suddenly or won't start, first check and top up the oil. If that doesn't solve the issue, check and replace the battery. Also, a blown fuse could be the cause, so check and replace the fuse if necessary.
  • B
    brendachandlerAug 26, 2025
    Why is my Altrad Construction Equipment low pressure, noisy and vibrating?
    • T
      Tyler DavisAug 26, 2025
      If you experience low pressure with your Altrad Construction Equipment, and the machine is noisy and vibrates, it could be due to several reasons. The valves may be worn or blocked, requiring cleaning or replacement. Alternatively, the piston seals might be worn and need replacement. Another potential cause is the pump sucking air, in which case you should check the water supply pipe and unions.
  • R
    Richard PowellAug 27, 2025
    What to do if Altrad Construction Equipment has sudden pressure loss?
    • D
      Darrell BondAug 28, 2025
      If your Altrad Construction Equipment experiences a sudden pressure loss, it might be due to a lack of water supply. Check the supply filters. Alternatively, there may be no chemical supply; in this case, check the chemical reservoir and close the valve.
  • D
    Danielle CameronAug 29, 2025
    Why is oil dripping from the pump bottom of my Altrad Construction Equipment?
    • J
      jonesrachelAug 29, 2025
      If you notice oil dripping from the bottom of the pump in your Altrad Construction Equipment, it's likely that the oil seal is worn and needs to be replaced.
  • Y
    ycollinsAug 31, 2025
    Why does my Altrad Construction Equipment have low pressure?
    • D
      David IbarraAug 31, 2025
      If you are experiencing low pressure with your Altrad Construction Equipment, it could be due to a worn high-pressure nozzle, which would require replacement. Another possible cause is an incorrectly set unloader; in this case, set the unloader to the correct setting.
  • R
    Rose GuerreroSep 3, 2025
    What to do if the pump will not by-pass on my Altrad Construction Equipment?
    • P
      Peter ChurchSep 3, 2025
      If the pump on your Altrad Construction Equipment will not bypass, it could be because the return valve is dirty or jammed. Clean or replace it as necessary.
  • C
    Cassandra HunterSep 4, 2025
    Why is water leaking from underneath my Altrad Construction Equipment?
    • L
      Leonard JohnsonSep 5, 2025
      If you notice water leaking occasionally from underneath your Altrad Construction Equipment, it could be due to worn pump seals. If the water in the pump is too hot, remove pressure by operating the lance.
  • A
    Angel SingletonSep 6, 2025
    Why is water dripping from the pump box of my Altrad Construction Equipment?
    • K
      Kimberly ClarkSep 7, 2025
      If you see water dripping from the pump box of your Altrad Construction Equipment, it's likely that the pump seals are worn and need replacement.

Summary

EC Declaration of Conformity

How To Use This Manual

Foreword

Introduction to the manual's purpose and scope.

Machine Description and Technical Data

General Safety Precautions

Health and Safety Guidelines

Pre-Start Checks and Inspections

Roller Striker Operating Instructions

Troubleshooting Guide for Roller Striker

Roller Striker Service and Maintenance

Roller Striker Spare Parts Book

Altrad BELLE Specifications

General IconGeneral
BrandAltrad
ModelBELLE
CategoryTrowels
LanguageEnglish

Related product manuals