12.3 If the CAVG reference number of a cylinder is above the HI SPARK VOLTAGE
threshold, a diagnostic warning for that cylinder will occur.
12.4 If the CAVG reference number of a cylinder is above the NO SECONDARY
SPARK threshold, a diagnostic warning for that cylinder will occur. This test
will identify cylinder firings that do not result in a spark — an open circuit
condition at the secondary of the coil resulting from a worn spark plug, or a
disconnected or failed secondary wire. To disable, set to 255.
12.5 If the difference between EAVG and CAVG reference numbers is greater than
the LO FROM ENGINE threshold, a diagnostic warning for that cylinder will
occur. This test will identify a cylinder whose voltage demand is too far below
the average engine voltage demand.
Default = 60
12.6 If the difference between CAVG and EAVG reference numbers is greater than
the HI FROM ENGINE threshold, a diagnostic warning for that cylinder will
occur. This test will identify a cylinder whose voltage demand is too far above
the average engine voltage demand.
Default = 60