CPU-95EVS OI 7-13
All rights reserved © ALTRONIC, LLC 2013
53
Enhanced Display Modbus Register 40000
Register Label Units Bits Min Max Default Notes
40001 MANUAL RETARD SETTING degrees * 10 16 0 65535 0 READ/WRITE
40002 CYLINDER TIMING OFFSET (A,A,A1) degrees * 10 16 0 65535 0 READ/W RITE
40003 CYLINDER TIMING OFFSET (B,B,A2) degrees * 10 16 0 65535 0 READ/WRITE
40004 CYLINDER TIMING OFFSET (C,C,B1) degrees * 10 16 0 65535 0 READ/W RITE
40005 CYLINDER TIMING OFFSET (D,D,B2) degrees * 10 16 0 65535 0 READ/WRITE
40006 CYLINDER TIMING OFFSET (E,E,C1) degrees * 10 16 0 65535 0 READ/WRITE
40007 CYLINDER TIMING OFFSET (F,F,C2) degrees * 10 16 0 65535 0 READ/WRITE
40008 CYLINDER TIMING OFFSET (K,G,D1) degrees * 10 16 0 65535 0 READ/WRITE
40009 CYLINDER TIMING OFFSET (L,H,D2) degrees * 10 16 0 65535 0 READ/WRITE
40010 CYLINDER TIMING OFFSET (M,K,E1) degrees * 10 16 0 65535 0 READ/WRITE
40011 CYLINDER TIMING OFFSET (N,L,E2) degrees * 10 16 0 65535 0 READ/WRITE
40012 CYLINDER TIMING OFFSET (P,M,F1) degrees * 10 16 0 65535 0 READ/W RITE
40013 CYLINDER TIMING OFFSET (R,N,F2) degrees * 10 16 0 65535 0 READ/WRITE
40014 CYLINDER TIMING OFFSET (S,P,K1) degrees * 10 16 0 65535 0 READ/WRI T E
40015 CYLINDER TIMING OFFSET (T,R,K2) degrees * 10 16 0 65535 0 READ/WRI T E
40016 CYLINDER TIMING OFFSET (U,S,L1) degrees * 10 16 0 65535 0 READ/WRI T E
40017 CYLINDER TIMING OFFSET (V,T,L2) degrees * 10 16 0 65535 0 READ/W RITE
40018 CYLINDER TIMING OFFSET ( U,M1) degrees * 10 16 0 65535 0 READ/WRI T E
40019 CYLINDER TIMING OFFSET ( V,M2) degrees * 10 16 0 65535 0 READ/WRITE
40020 CYLINDER TIMING OFFSET ( N1) degrees * 10 16 0 65535 0 READ/WRITE
40021 CYLINDER TIMING OFFSET ( N2) degrees * 10 16 0 65535 0 READ/WRI T E
40022 –
40215
RESERVED - 16 0 65535 0
40216 CYLINDER LABEL (A,A,A1) - 16 0 65535 0 READ/WRI T E
40217 CYLINDER LABEL (B,B,A2) - 16 0 65535 0 READ/W RITE
40218 CYLINDER LABEL (C,C,B1) - 16 0 65535 0 READ/WRI T E
40219 CYLINDER LABEL (D,D,B2) - 16 0 65535 0 READ/WRITE
40220 CYLINDER LABEL (E,E,C1) - 16 0 65535 0 READ/WRI T E
40221 CYLINDER LABEL (F,F,C2) - 16 0 65535 0 READ/WRI TE
40222 CYLINDER LABEL (K,G,D1) - 16 0 65535 0 READ/WRITE
40223 CYLINDER LABEL (L,H,D2) - 16 0 65535 0 READ/WRI TE
40224 CYLINDER LABEL (M,K,E1) - 16 0 65535 0 READ/W RITE
40225 CYLINDER LABEL (N,L,E2) - 16 0 65535 0 READ/W RITE
40226 CYLINDER LABEL (P,M,F1) - 16 0 65535 0 READ/WRI T E
40227 CYLINDER LABEL (R,N,F2) - 16 0 65535 0 READ/W RITE
40228 CYLINDER LABEL (S,P,K1) - 16 0 65535 0 READ/WRITE
40229 CYLINDER LABEL (T,R,K2) - 16 0 65535 0 READ/WRITE
40230 CYLINDER LABEL (U,S,L1) - 16 0 65535 0 READ/WRI T E
40231 CYLINDER LABEL (V,T,L2) - 16 0 65535 0 READ/WRITE
40232 CYLINDER LABEL ( U,M1) - 16 0 65535 0 READ/WRITE
40233 CYLINDER LABEL ( V,M2) - 16 0 65535 0 READ/W RITE
40234 CYLINDER LABEL ( N1) - 16 0 65535 0 READ/WRI TE