7 Servicing/Maintenance
65 of 124
Amarex KRT
7.2.3 Lubrication and lubricant change
7.2.3.1 Lubricating the mechanical seal (pump sets without cooling system only —
installation type S)
7.2.3.1.1 Intervals
Replace the lubricant every 8000 operating hours but at least every 2 years.
7.2.3.1.2 Lubricant quality
The lubricant chamber is filled at the factory with environmentally friendly, non-toxic
lubricant of medicinal quality (unless otherwise specified by the customer).
The following lubricants can be used to lubricate the mechanical seals:
Table36: Lubricant quality
Description Properties
Paraffin oil
or
white oil.
Alternative: motor oil
grades SAE10W to
SAE20W
Kinematic viscosity
at 104°F [40°C]
< 0.065ft/s
2
[<20mm/s
2
]
Flash point (to Cleveland) > 320°F [>160°C]
Solidification point (pour point) < -5°F [< -15°C]
Recommended lubricants: ▪ Merkur WOP 40 PB, made by SASOL
▪ Merkur white oil Pharma 40, made by DEA
▪ Thin-bodied paraffin oil No. 7174, made by Merck
▪ Equivalent brands of medical quality, non-toxic
▪ Water-glycol mixture
WARNING
Contamination of fluid handled by lubricant
Hazard to persons and the environment!
▷ Using machine oil is only permitted if the oil is disposed of properly.
7.2.3.1.3 Lubricant quantity
Table37: Lubricant quantity depending on the motor
Size Motor
5306
5806
6306
4608
5308
5808
39010
43010
47510
34012
38012
6906
7706
8506
6308
6908
7608
53510
60010
66010
45012
49012
56012
Lubricant quantity
[quart] [l] [quart] [l]
200-631 5,7 5,4 4,8 4,5
250-630 5,7 5,4 4,8 4,5
250-632 5,7 5,4 4,8 4,5
250-900 5,7 5,4 4,8 4,5