7 Servicing/Maintenance
70 of 124
Amarex KRT
Size Motor
5306
5806
6306
4608
5308
5808
39010
43010
47510
34012
38012
6906
7706
8506
6308
6908
7608
53510
60010
66010
45012
49012
56012
[oz] [g] [oz] [g]
700-901 6,0 170 7,4 210
700-902 6,0 170 7,4 210
7.2.3.2.3 Re-lubrication
Lubricating nipple An encapsulated water-tight lubricating nipple allows re-lubrication of the angular
contact ball bearings without opening the pump.
DANGER
Dry running
Explosion hazard!
▷ Re-lubricate nonincendive pump sets outside potentially explosive atmospheres.
WARNING
Hands inside the pump casing
Risk of injuries, damage to the pump!
▷ Never insert your hands or any other objects into the pump if the pump has not
been de-energized and secured against unintentional start-up.
CAUTION
Incomplete re-lubrication
Bearing damage!
▷ Always re-lubricate the bearings with the pump set in operation.