EasyManua.ls Logo

Ambu aView 2 Advance - User Manual

Ambu aView 2 Advance
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
For use by trained healthcare professionals only. For
use with compatible Ambu
®
visualisation devices.
Ambu
®
aView
2 Advance
INSTRUCTIONS
FOR USE

Table of Contents

Other manuals for Ambu aView 2 Advance

Questions and Answers

  • A
    Amy RodriguezAug 16, 2025
    How to fix Ambu Monitor when it does not turn on?
    • R
      Rachel RamosAug 16, 2025
      If your Ambu Monitor isn't turning on when you press the power button, it might be due to one of the following reasons: * The battery might be completely drained. If this is the case, connect the power supply to the displaying unit. * Even with the power supply connected, the unit might not turn on if the power supply itself is faulty. Check if the light on the power supply is on when plugged into a working wall socket. If there's no light, the power supply may need replacement. You can also try performing a Power OFF Cycle.
  • A
    Andrea JohnsonAug 19, 2025
    Why is there no image on the external monitor connected to my Ambu Monitor?
    • K
      Karen RoblesSep 12, 2025
      If you're not seeing an image or user interface on the external monitor connected to your Ambu Monitor, consider these possible causes: 1. The external monitor might be turned off. Ensure it is turned on. 2. There could be a problem with the cable or its connection. Check that the SDI or HDMI cable is correctly connected. If possible, try using a new, high-quality cable with better shielding. 3. The wrong input channel might be selected on the external monitor. Make sure the correct input channel is selected. 4. If using SDI, the external monitor might not support 3G-SDI. Verify that your external monitor supports 3G-SDI (1920 x 1080 p 60 fps).
  • K
    Kristin HollandAug 25, 2025
    Why is Ambu Monitor battery not charging?
    • A
      Angela ReevesAug 25, 2025
      If the battery of your Ambu Monitor is not charging, it could be because the internal temperature in the displaying unit is either too low (below 10 °C) or too high (above 45 °C). To resolve this, ensure the following: 1. The back of the monitor has free access to airflow. 2. The fan is running. Check this by looking through the ventilation holes, feeling for airflow, or listening for fan noise. If the fan isn't running, it may need replacement. 3. The displaying unit is not placed in direct sunlight or exposed to other heat sources.
  • T
    Thomas WolfAug 27, 2025
    How to troubleshoot Ambu Monitor when it does not recognize a USB device?
    • S
      Sarah NixonAug 27, 2025
      If your Ambu Monitor isn't recognizing a connected USB device, here are some potential reasons and solutions: * The USB connector port might be damaged. Try using a different USB connector port. * The USB cable or the external USB device itself could be damaged. Try connecting a new USB cable or a new USB device. * There might be internal communication problems within the displaying unit. Perform a Power OFF Cycle. * The USB connection might be disabled in the settings. Log in as an Administrator and go to Settings – Setup – General settings to enable USB connection.
  • D
    Dr. Jill WoodsAug 30, 2025
    Why is the picture quality on my Ambu Monitor low?
    • B
      Brandon ZavalaAug 30, 2025
      If you're experiencing low picture quality on your Ambu Monitor, here are a few things to check: * The screen might be dirty or damp. Wipe the screen with a clean cloth. * The image adjustment settings might not be optimal. Open the Image Adjustment menu to adjust colour, contrast, sharpness, and brightness. * The distal end of the visualization device might be dirty or damp. Refer to the Instructions for Use of the visualization device for cleaning instructions.
  • S
    Sean KellySep 1, 2025
    What causes low battery uptime on Ambu Monitor?
    • M
      Megan CummingsSep 2, 2025
      If you find that the battery life of your Ambu Monitor is less than 1 hour after a full charge, it's likely that the internal battery's capacity has degraded due to wear and tear. In this case, consider replacing the battery.
  • P
    Peter GarnerSep 4, 2025
    Why does the live image on Ambu Monitor only work while booting?
    • A
      Amy BurnsSep 5, 2025
      If the live image on your Ambu Monitor's screen only appears during the booting process, it could indicate a processing failure. Try performing a Power OFF Cycle to resolve this.
  • T
    theresasavageSep 7, 2025
    What to do if the touch interface on my Ambu Monitor is not responding?
    • J
      James FerrellSep 7, 2025
      If the touch interface on your Ambu Monitor isn't responding, it could be due to internal communication problems within the displaying unit. Try performing a Power OFF Cycle to resolve this.
  • A
    Amanda StricklandSep 10, 2025
    Why do colors look different on the external monitor connected to Ambu Monitor?
    • H
      Holly MillerSep 10, 2025
      If the colors, contrast, sharpness, and brightness appear different on the external monitor compared to the Ambu Monitor's screen, it's likely that the image settings on the external monitor are not correctly adjusted. Adjust the image settings on the external monitor to achieve the desired result. Refer to the Instructions for Use for the external monitor for guidance.
  • A
    Amanda KimSep 13, 2025
    What to do if data transfer fails from Ambu Monitor to USB?
    • M
      Mike MortonSep 13, 2025
      If you're experiencing failed data transfers from your Ambu Monitor to a USB flash drive, the issue might be due to an incorrect USB format. The displaying unit supports data transfer to USB flash drives formatted as exFAT, EXT4, NTFS, BTRFS, and FAT32. Ensure your USB drive is formatted in one of these formats.

Summary

Safety and Usage Precautions

Key Warnings and Cautions

Lists essential safety instructions, warnings, and precautions for operating the unit.

Device Overview and Compatibility

Compatible Visualization Devices

Details Ambu visualization devices compatible with the aView 2 Advance.

Endoscope Activation

Initial Setup Guide

First-Time Setup Steps

Guides users through the initial setup process of the displaying unit.

Administrator Login & Password

User Profile Management

General Settings Configuration

Network Setup

Wi-Fi & LAN;Ethernet Setup

Details how to connect the displaying unit to a network via Wi-Fi or Ethernet.

PACS and Worklist Setup

Operating the Unit

Preparation and Inspection

Steps for checking and preparing the displaying unit prior to a procedure.

Endoscope Button Setup

How to customize the function of endoscope buttons for different procedures.

Starting and Stopping Procedures

Worklist Workflow

Live View Functions

Image Adjustments

Photos and Video Capture

After-Use Procedures

Archive File Handling

Exporting Files

Steps for transferring files to external storage or a PACS server.

Deleting Archive Files

External Equipment Connections

Medical Printer Printing

System Info & Software Updates

Software Updates

Reporting Problems

Data Reset

Cleaning and Disinfection

Enzymatic Detergent & Alcohol Disinfection

Disposal and Specifications

aView 2 Advance Specs

Technical details of the displaying unit, including display, connections, and memory.

Troubleshooting

Power Cycle Troubleshooting

Steps for power cycling the unit to resolve common operational problems.

Live Image & Connectivity Troubleshooting

Touch Interface Issues

FCC Wi-Fi Compliance

Cybersecurity

Data Security

Ambu aView 2 Advance Specifications

General IconGeneral
Resolution1280 x 800 pixels
Input Voltage100-240 VAC, 50/60 Hz
TouchscreenYes
Brightness400 cd/m²
Contrast Ratio800:1
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Data ExportUSB, Wi-Fi
Weight1.5 kg
ConnectivityWi-Fi, Bluetooth
Battery TypeLithium-ion
Video InputHDMI
Supported ParametersECG, SpO2, NIBP
Display Size12.1 inches