11
Service Department: 888.270.6879
ALWAYS lock o power rst.
Daily cleaning (Aer 8 hours of operaon)
Remove debris that has built up on the cuers and combers using compressed air (maximum 40 psi) or
vacuum.
Use heavy gloves to remove magnec material from cuer-head.
Visually inspect cuers for damage.
Replace all guards.
Weekly cleaning (Aer each 40 hours of operaon)
Repeat all daily cleaning steps.
Remove debris buildup from base.
Wipe enre machine clean being careful to observe any evidence of oil leaks. Should leakage be observed,
request the aenon of the appropriate maintenance personnel.
Remove all tools, rags, solvents from machine.
Replace all guards.
MAINTENANCE - CLEANING
ALWAYS lock o power rst.
Daily lubricaon (Aer 8 hours of operaon)
Apply light machine oil to cuers.
Weekly lubricaon (Aer each 40 hours of operaon)
Repeat steps from daily lubricaon.
Remove guards.
Apply open gear lube or grease to spur gears.
Replace all guards.
Monthly lubricaon (Aer each 160 hours of operaon)
Repeat steps from weekly lubricaon.
Remove guards
Check reducer oil level. DO NOT OVERFILL.
Grease output conveyor bearings using a mulpurpose
lithium based grease.
Replace all guards.
Annual lubricaon (Aer 2080 hours of operaon)
Repeat steps from monthly lubricaon.
Drain oil from reducer.
Clean magnec drain plug.
Replace drain plug and rell to proper level using a high grade petroleum based, rust and oxidaon inhibited
gear oil.
CE
CAUTION:
Too much oil will cause over heang, and too lile oil will result in gear failure. Check oil level monthly.
Also, under extreme operang condions, such as rapid rise or fall of temperatures, dust, dirt, chemical
parcles, chemical fumes, or oil temperatures above 200° F, the oil should be changed every one to
three months depending on the severity of condions.
MAINTENANCE - LUBRICATION
Spur Gears