11
Version 06.2019           www.dunkermotoren.com    BG 75 EC
3.2 Electrical data
Permissible  
speed range
0...5000 rpm 
Permissible motor voltage 10...50 VDC
Low-voltage cut-o 
motor
< 10 VDC 
Permissible control voltage  24 VDC +/- 20%
Low-voltage cut-o 
logic
< 18 VDC
Permissible ripple  Max. 5%
Fuse  required externally
Over-temperature cut-o
> 115°C temperature 
of output stage PCB
Max. peak current in  
the motor phase
50 A
Current draw of 24V logic 
supply 
1
70 mA + DOs
1 
This value is only correct without using of an encoder 
and when the digital outputs are unloaded. Additional 
components connected to the outputs increase the 
current consumption.
 
2
 See also chapter 5.3 current limitation and the  
   following tables chapter 3.2.1 to 3.2.3
3.2 Elektrische Daten
Zulässiger 
Drehzahlbereich
 0...5000 rpm
Zulässige Motorspannung  10...50 VDC
Unterspannungs-
abschaltung Motor
 < 10 VDC 
Zulässige Steuerspannung 24 VDC +/- 20%
Unterspannungs-
abschaltung Logik
< 18 VDC
Zulässige Restwelligkeit Max. 5%
Absicherung  extern erforderlich
Übertemperaturabschaltung
> 115°C Temperatur 
der Endstufen-
Leiterplatte
Max. Spitzenstrom in der 
Motorphase 
 50 A
Stromaufnahme der 
24V-Logikversorgung 
1
 70 mA + DOs
1 
Dieser Wert gilt nur bei Betrieb ohne zusätzlichen  
Drehgeber und unbelasteten digitalen Ausgängen. 
Eventuell an den Ausgängen angeschlossene Kompo-
nenten erhöhen den Strombedarf entsprechend.
 
2
 Sie hierzu auch Kapitel 5.3 Strombegrenzung und
    die nachfolgenden Tabellen Kapitel 3.2.1 bis 3.2.3
  Überschreiten der maximal zulässigen  
 Dauerströme!
  DieFolge:
  Die  interne Elektronik/ Motor kann  
  zerstört werden. 
 
►DiemaximalzulässigenDauerströme 
    beachten
! 
2
VORSICHT
  Exceeding of the maximum permitted  
  continuous current!
  Consequence:
    The integrated electronics/ motor may  
    be destroyed.
 
►Mindthemaximumpermitted 
    continuous current!
 
2
 
CAUTION