EasyManua.ls Logo

Ametek Sorensen DCS8-350E - Page 54

Ametek Sorensen DCS8-350E
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Advanced Operation Sorensen DCS-E Series 3kW Supplies
4-10 M362295-01 Rev D
Figure 4-5 Programming Output Voltage with a 0-10 Vdc Source
WARNING
Exercise caution when resetting internal jumpers. Review Section 2.2 Safety and
follow procedures for removing the cover and resetting jumpers in Section 4.2.3
Resetting Jumpers and Switch.
P
ROGRAMMING
O
UTPUT
V
OLTAGE WITH A
0-1
M
A
S
OURCE
1. Remove the jumper between pins 20 and 21 of connector J3.
2. Connect the external programming source between pin 9 (voltage programming
input/positive) and pin 12 (return) of connector J3.
Varying the current source from 0 to 1 mA will vary the output voltage from 0 to 100% of the
model rating. Adjusting the front panel current limit control sets the output current limit.
Figure 4-6 Programming Output Voltage with a 0-1 mA Source

Table of Contents