Remote Operation 
 
M370430-01  Rev F  5-71 
Save and Recall 
The save and recall of user settings can be done using commands as well 
as at the front panel. Executing the save and recall commands will have 
the same outcome as following the procedure outlined in “Saving User 
Setting Memory Locations” on page 3-39 and “Recalling User Setting 
Memory Locations” on page 3-40. 
Commands: 
[:]SYSTem[<channel>]:SAVE   {<user   settings   slot>}  
[:]SYSTem[<channel>]:RECall {<user   settings slot>}  
Where 
<user settings slot> is any integer between 1 and 3. The value 
corresponds to the setting to be operated on. 
Set Analog Programming Level 
Setting the analog programming level is used to define the range from 0 
to the level that will be input into the analog programming lines to 
control the output. The command is equivalent to the procedure 
described in “Analog Programming Mode” on page 4-9. 
Commands: 
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel 
[:VOLTage][:ISOLated] {?|<level>} 
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel 
[:VOLTage] {?|<level>} 
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel  
:CURRent[:ISOLated] {?|<level>} 
[:]SYSTem[<channel>]:COMMunicate:APRogram:LEVel  
:CURRent {?|<level>} 
Where 
<level> is the maximum voltage or resistance that will be input to the 
analog inputs.The acceptable range is from 2 to 10 V and 2 to 10kΩ.