EasyManua.ls Logo

Ametek Sorensen XG 40-21 - Table A-7 SCPI Commands for Power

Ametek Sorensen XG 40-21
399 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M370430-01 Rev F A-23
A
APPENDIX A
SCPI Command Reference
Table A-7 SCPI Commands for Power
Function
SCPI Command
Description
Parameter and
Range
Query
Shutdown
Logic Control
[:]OUTPut:POLarity
Sets the TTL level that will
trigger an External
Shutdown.
?|HIGH|LOW
Yes
Main Output
Control
[:]OUTPut[:POWer][:STATe]
Control Main Output State
(Enable/Disable)
?|ON|OFF
Yes
Power On
Main Output
Control
[:]OUTPut[:POWer]:PON[:STATe]
Control Main Output
Autostart State (Enable/
Disable)
?|ON|OFF
Yes
Aux Output
Control
[:]OUTPut:AUXilliary[:STATe]
Control Aux Output State
(Enable/Disable)
?|ON|OFF
Yes
Power
Auxiliary
Output Control
[:]OUTPut:AUXilliary:PON[:STATe]
Control Aux Output
Autostart State (Enable/
Disable)
?|ON|OFF
Yes
Table A-8 SCPI Commands for Triggering
Function
SCPI Command
Description
Parameter and
Range
Query
Set Immediate
Initiation of
Trigger System
[:]INITiate[<channel>][:IMMediate]
Triggers the Autosequence
Program.
N/A

Table of Contents