APPENDIX E
Lantronix Procedures for MEA Option
E-20 M370430-01 Rev F
Figure E-23 System with Two Connected Devices
Figure E- shows a system with two connected devices.
Important: In this system configuration, every power supply needs a unique IP
address, whereas the address defined from front panel (power supply’s own
address) may be arbitrary.
Network Topology 2: ENET and RS-485 Bus
Up to 30 units may be connected to the RS-485 bus. The first unit
connects to the controller via ENET, and the other units are connected
with the RS-485 bus.
Figure E-24 shows the system of a unit with the ENET option and
several units connected via the RS-485 bus. Each power supply must
have its own address, defined from the front panel. Only one IP address
is required for your network (excluding computers) and only one