Signaling:
The device has 3 different types of signaler, each of which can
be used to confirm inputs such as arm / disarm, or press a
button and can be combined as desired.
Buzzer:
a short beep sound from the device. To control press the
"Buzzer" button briefly, less than 0.5 seconds (i.e. just tap). If
the device beeps for a long time, the signal transmitter is
switched on. If it beeps twice, it is switched off.
Siren:
To control, press the "Buzzer" button for 1-3 seconds (i.e. keep
it pressed). If the siren beeps once, the siren is switched on.
If it beeps twice, it is switched off.
Vibration:
The device has a built-in vibration motor, which sets the
housing in a slight vibration, to allow the quietest possible
signaling. To control press the "Buzzer" button for more than 3
seconds. If the device hums once long, the signal generator is
switched on, if it hums 2 times short, it is switched off.
8. Adjusting the CarPro-Tec® GPS Infrasound-Sensor
Increase sensitivity -> Turn right
Reduce sensitivity-> Turn left
In this case, the activation of the beep by the "Buzzer" button (see above) is helpful in
order to acoustically indicate the switching state (arming).
Please note that a violent leveraging of doors and windows by a vehicle thieve causes
them to be opened with a jerk. No vehicle thieve can open a locked door or window "in
slow motion" very carefully and slowly. Therefore, please set the sensitivity so that the
alarm will be triggered by a small jerky opening of doors or windows.
If you set the sensitivity too high, it will lead to unwanted false triggering, i.e. due to
drafts due to incompletely closed and sealed windows, ventilation flaps, etc.
Fine-tuning the sensitivity might require readjustment 2-3 times during practical tests.
If there is a short time after the first startup of the system and an alarm triggers, this
may well be a "false" alarm due to too high set sensitivity of the sensor. In this case
reduce the sensitivity on the knob very slightly to the left and then observe again.