NOTICE
1. Read this manual thoroughly before using the Axpert-Eazy, and store in a safe place for reference.
2. Make sure that this manual is delivered to the final user.
200 V System, 11 kW (15 Hp) ~ 90 kW (125 Hp)
400 V System, 22 kW (30 Hp) ~ 1550 kW (2075 Hp)
500 V System, 30 kW (40 Hp) ~ 1550 kW (2075 Hp)
600 V System, 30 kW (40 Hp) ~ 1800 kW (2415 Hp)
Instruction Manual
Axpert-Eazy Series
AMTECH
IMAE-01, Rev. 1.20
JUL 2017
AMTECH

Table of Contents

Questions and Answers

  • C
    Curtis HuffmanSep 4, 2025
    What causes Under Voltage Fault in Amtech Axpert-Eazy AMT-200-4 DC Drives?
    • J
      Juan GrossSep 4, 2025
      An Under Voltage Fault in Amtech DC Drives can be caused by the DC Bus voltage falling below the under voltage level. Check the input power supply and correct it if necessary. Also check soft charge contactor or connection.
  • J
    joneschadSep 2, 2025
    What to do if Amtech Axpert-Eazy AMT-200-4 DC Drives have Thermistor Over Temperature Fault?
    • L
      Lori WalkerSep 2, 2025
      If your Amtech DC Drive is showing a Thermistor Over Temperature Fault, it could be due to several reasons. A trouble may have occurred in the cooling blower, so replace it if necessary. The ambient temperature may have risen, so lower the ambient temperature (less than 50 °C for 400 V series or less than 40 °C for 500 V / 600 V series). The temperature switch (thermostat) or thermistor may not be connected or loosely connected at J16 and J13 respectively, so disconnect thermostat switch connection at J16 and ensure that the thermostat shows short circuit. Disconnect the thermistor and ensure that the thermistor shows resistance greater than 2.2 kΩ but less than 60 kΩ. Reconnect thermostat and thermistor properly.
  • M
    mnicholsAug 31, 2025
    How to fix U Phase Current Sensor Fail Fault on Amtech DC Drives?
    • K
      Kyle SnyderAug 31, 2025
      To address a U Phase Current Sensor Fail Fault on Amtech DC Drives, first, check for a loose connection of the hall current sensor cable connected at J12 of PCA-2014A. Switch off the unit, remove the cable, and inspect both sides for proper crimping. If you find any issues, replace the cable and check again. Second, one or more current sensors may have failed. Remove connector J12 and reset the fault. If the fault can be reset, identify the failed current sensor. If, after removing connector J12, the problem persists, replace PCA-2014A.
  • S
    Sandra GoldenAug 29, 2025
    What causes an Adjustable Over Current Fault in Amtech Axpert-Eazy AMT-200-4 DC Drives?
    • J
      Jennifer PinedaAug 30, 2025
      An Adjustable Over Current Fault in Amtech DC Drives can be triggered by a few factors. The motor current data might be set incorrectly, so set correct motor current data in B103. Alternatively, the adjustable over current settings may be too low, so increase the adjustable over current level (B302). Finally, the output current might be too high, so reduce the motor load.
  • T
    Tina WheelerAug 28, 2025
    What to do if Amtech Axpert-Eazy AMT-200-4 DC Drives display a Communication Loss?
    • J
      Jeffrey SantanaAug 28, 2025
      If an Amtech DC Drive displays a Communication Loss, it could be due to several reasons. There may be a problem in display board PCA-2012, so replace the display board PCA-2012 and check again. Also, there may be a problem in control board PCA-2014A. If +5 V supply or +3.3 V supply is not coming then also this fault will come. Check the power supply unit and if problem is found replace it, or replace the DSP control board PCA-2014A and check again. You can also disable the fault using C405. This will allow the inverter to run in case of communication loss between the PCA-2014A DSP control board and PCA-2012 LCD display board.
  • J
    Joseph AllenAug 26, 2025
    Why does my Amtech DC Drive show a Drive Over Load Fault?
    • D
      Dr. Daniel WellsAug 26, 2025
      An Amtech DC Drive may show a Drive Over Load Fault because the AC drive is overloaded. Ensure that motor current data are properly set in B103. Reduce the load or increase the motor and AC DRIVE capacity. If this occurs at low speed, reduce the torque boost settings (A501 / A502) or DC braking settings (A307 / A308).
  • M
    Melissa CarterAug 25, 2025
    What to do if my Amtech DC Drives show a Ground Fault?
    • M
      Mark ChandlerAug 25, 2025
      If your Amtech DC Drive indicates a Ground Fault, it may be due to a short in the output line or motor. Check that no output is shorted to ground; partially damaged output cables can also cause this. Another possibility is a problem with one or more current sensors. Remove the current sensor feedback and check. If the fault persists, replace PCA-2014A, otherwise replace the problematic current sensor.

Summary

Instruction Manual Axpert-Eazy Series

Preface

Precautions For Safety

Essential safety guidelines to prevent hazards and ensure correct usage.

Chapter 1: Delivery, Inspection and Storage

1-1 Delivery, Inspection and Storage Procedures

Guidance on receiving, inspecting, and storing the AC drive unit safely.

Chapter 2: Installation and Wiring

2-1 Installation Environment Guidelines

Recommendations for selecting a suitable installation location and ventilation.

2-2 Precautions for Power Supply and Motor Wiring

Critical safety warnings and procedures for connecting power supply and motor.

2-4 Precautions for Control Signals Wiring

Guidelines for wiring control circuits to prevent interference and ensure safety.

Chapter 3: Digital Operation Panel (LCD Keypad Module)

3-3 Parameter Display & Setting Procedures

Step-by-step guide on navigating and changing parameter values.

Chapter 4: Test Operation and Adjustment

4-1 Preparation Before Turning Power ON

Essential checks and preparations before energizing the drive.

4-2 Initialization of Motor Constants in Mode-B

Procedure for entering motor rating parameters for proper operation.

4-3 Automatic Tuning & Adjustment

Guide to performing automatic tuning for optimal motor performance.

Chapter 5: Control Input; Output Terminals

Chapter 6: Parameter Settings & Functions

MODE-A: Parameter Details

Comprehensive list and explanation of parameters for Mode-A.

MODE-B: Parameter Details

Comprehensive list and explanation of parameters for Mode-B.

MODE-C: Parameter Details

Comprehensive list and explanation of parameters for Mode-C.

Chapter 8: Maintenance, Inspection and Part Replacement

8-1 Inspection Items Overview

Scheduled inspections and checks required for the AC DRIVE.

Chapter 11: Serial Communication Set-Up

11-1 Connection Method Overview

Configuration details for connecting host computer and Axpert-Eazy units via RS485.

11-4 Communication Specifications

Technical details of the serial communication interface and protocol.

11-5 Introduction to Modbus

Overview of the Modbus protocol, transactions, and transmission modes.

Chapter 12: UL Instructions

12-1 UL;cUL Compatible Product Observations

Key points to observe when using the inverter as a UL/cUL compatible product.

Chapter 13: CE Marking

13-1 Installation Environments for EMC Compliance

Guidelines for installation environments to meet EMC directives.

13-2 Input Filters and Their Connections

Precautions and connection details for input filters to manage electrical shock hazards.

13-3 Wiring & Earthing Practices

Recommendations for wiring and earthing to reduce EMI and ensure immunity.

Appendix-B: Fault Codes

Appendix-C: Trouble Shooting Guidelines

Amtech Axpert-Eazy AMT-200-4 Specifications

General IconGeneral
BrandAmtech
ModelAxpert-Eazy AMT-200-4
CategoryDC Drives
LanguageEnglish