2
SCPI Device Message Details
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:WIDTh:TYPE ZONE|SPOT
Zone Width Type
Function
This command sets the zone type of the marker.
Command
:CALCulate:MARKer[n]:WIDTh:TYPE <zone_type>
Parameter
<n>
Marker number
1
Marker 1
2
Marker 2
3
Marker 3
4
Marker 4
5
Marker 5
6
Marker 6
7
Marker 7
8
Marker 8
9
Marker 9
10
Marker 10
When omitted:
Marker 1
<zone_type>
Zone type of Marker
ZONE
Zone marker
SPOT
Spot marker
Details
This command is available when Marker Result is Peak.
When Marker Result is set to Integration or Density, Zone type is fixed
to Zone, Spot cannot be selected.
This command is not available in the following cases:
•
During the time domain measurement.
•
During Spurious Emission measurement when Displayed Segment
Mode is Auto.
•
During Spectrum Emission Mask measurement.
Example of Use
To set the zone type of the marker in the marker 1 to zone marker.
CALC:MARK:WIDT:TYPE ZONE