114
10. [PCC/SCC] Execute TESTPRM TX_MAXPWR_Q_P to set Test Parameter to TX1 – Max. Power
(QPSK/PartialRB).
11. Execute steps 7 to 9.
3.3.1.1.2. MT8821C
[Acceptable Value Setting]
1. Execute PWR_AVG 20 to set the average count for Power Measurement to 20
2. Execute TP_MAXPWR_LL 20.3 to set TX1 – Max. Power (QPSK/1RB/PartialRB) Pass/Fail lower limit to 20.3
dBm.
3. Execute TP_MAXPWR_UL 25.7 to set TX1 – Max. Power (QPSK/1RB/PartialRB) Pass/Fail upper limit to 25.7
dBm.
[(QPSK, 1RB) measurements]
1. Execute TESTPRM TX_MAXPWR_Q_1 to set Test Parameter to TX1 – Max. Power(QPSK/1RB).
2. Execute ULRB_POS MIN to set PCC UL RB Position to Min(#0).
3. Execute ULRB_POS_SCC1 MIN to set SCC–1 UL RB Position to Min(#0).
4. Execute SWP to measure the Power.
5. Execute POWER? AVG,PCC to read the PCC TX power measurement result.
6. Execute POWERPASS? PCC to check that the PCC TX power measurement Pass/Fail judgment is Pass.
7. Execute POWER? AVG,SCC1 to read the SCC–1 TX power measurement result.
8. Execute POWERPASS? SCC1 to check that the SCC–1 TX power measurement Pass/Fail judgment is Pass.
NOTE 1: The tolerance (lower limit) is relaxed by 1.5dB for transmission bandwidths confined within F
UL_low
and F
UL_low
+ 4 MHz or F
UL_high
– 4 MHz and F
UL_high
.
NOTE 2: The Band 1 tolerance value defined in TS36–521–1 is set as the initial value for Pass/Fail
judgment.
The following Pass/Fail judgment values change depending on the bands.
TP_MAXPWR_LL
TP_MAXPWR_UL