Chapter 4 OTDR Commands
4-20
4.4.21 SENSe:LSALeft? Command
Syntax: SENSe:LSALeft?
Parameters: None
Description: Query left LSA values.
Example: sens:lsal? --- 0.0, 0.5<END>
Response: Start and stop for left LSA marker. Start and stop units – kilometers (KM).
Errors: (–400, "std_queryGen, LSA Inactive State")
4.4.22 SENSe:LSARight Command
Syntax: SENSe:LSARight<wsp><start>,<stop>
Parameters: <start>
Floating point format
Range: –100.0 – 400.0.
<stop>
Floating point format
Range: –100.0 – 400.0.
Start value must be less or equal to stop value.
Description: Set start and stop for right LSA marker. Start and stop units – kilometers (KM).
Example: sens:lsar 0.0, 0.5
Response: None
Errors: (–224, "std_illegalParmValue, Invalid Parameter Value")
(–200, "std_execGen, LSA Inactive State")
4.4.23 SENSe:LSARight? Command
Syntax: SENSe:LSARight?
Parameters: None
Description: Query right LSA values.
Example: sens:lsar? --- 0.0,0.5<END>
Response: Start and stop for right LSA marker. Start and stop units – kilometers (KM).
Errors: (–400, "std_queryGen, LSA Inactive State")