Anton Paar DMA 4100 M Specifications

General IconGeneral
Measurement PrincipleOscillating U-tube
Viscosity CorrectionYes
Measuring Range (Density)0 to 3 g/cm³
Accuracy (Density)0.0001 g/cm³
Repeatability (Density)±0.00005 g/cm³
Temperature Accuracy0.03 °C
Temperature Repeatability±0.01 °C
Sample Volume1 mL
DisplayColor display
ConnectivityUSB, Ethernet
Data Storage1000 results
Power Supply100-240 V

Summary

About the Instruction Manual

Safety Instructions

The Measuring Principle

The Instrument - An Overview

Features and Benefits

Highlights key technological advancements and operational advantages of the DMA M series instruments.

User Interface

Describes the touch screen interface and operation methods for user interaction.

Functional Components

View of the Front and Right Side

Details the layout and components visible on the front and right side of the instrument.

View of the Left Side

Illustrates and describes the components located on the left side of the instrument.

Rear View

Provides a detailed diagram and explanation of the connectors and ports on the rear of the instrument.

Operating Elements of the Main Screen

Explains the different areas and buttons on the instrument's main operational screen.

Operating Elements of the Menu Screen

Describes the structure and interaction elements within the instrument's menu system.

Installing the Instrument

The Right Place

Specifies the ideal environmental conditions and location requirements for instrument installation.

Mounting the Injection Adapters

Provides instructions for correctly attaching the injection adapters to the instrument.

Checking for Leak Tightness

Outlines the procedure to verify that the installed injection adapters are leak-free.

Mounting the Hoses

Details the steps for connecting the necessary hoses for waste and air pump functions.

Switching the Instrument On/Off

Explains the procedure for powering the instrument on and off.

Instrument Settings and First Checks

Guides on initial instrument configuration and essential verification steps after installation.

Operating the Instrument

Input Alternatives

Lists the different methods available for user input and interaction with the instrument.

Using the External Keyboard

Explains how to use an external keyboard for instrument control and data entry.

Using the Touch Screen

Details the operation of the instrument using its integrated touch screen interface.

Calibrating the Touch Screen

Describes the process for recalibrating the touch screen for accurate input.

Setting the Screen Saver

Explains how to configure the automatic screen saver activation time.

Activating/Deactivating the Feedback Beeps

Covers the settings for enabling or disabling audible feedback from the instrument.

Logging On/Off

Details the procedures for user authentication and session management on the instrument.

Using Favorites

Explains how to configure and use the favorites function for quick access to frequently used features.

Installing Optional Input/Output Devices

External Keyboard, Bar Code Reader, Mouse

Guides on connecting and using external input devices like keyboards, mice, and barcode readers.

USB Flash Drive

Instructions for using a USB flash drive for data storage and transfer with the instrument.

Printer

Information on connecting and configuring different types of printers with the instrument.

External Terminal or Data Projector

Details on connecting external display devices for enhanced visualization.

External Touch Screen

Instructions for connecting and using an external touch screen monitor.

Defining General Settings

Instrument Settings

Covers essential instrument configurations like date, time, regional preferences, and units.

Date and Time

Procedure to set the instrument's current date and time.

Regional Settings

Configuration of language, data formats, and keyboard layout for local adaptation.

Input Units

Defines the units used for temperature and other measurements.

Air Pump Settings

Configuration options for the instrument's air pump operation and timeouts.

Saving a Camera Picture (DMA 4500/5000 M Only)

Settings to control automatic saving of images from the instrument's camera.

Network

Configuration of network connectivity for data transfer and remote access.

Instrument Name and Location

Assigns a unique name and location to the instrument for identification.

Defining the Printout Settings

Customizes the layout and content of printer reports.

Creating, Editing and Deleting Printer Report Layouts

Manages predefined or custom layouts for printing measurement results.

Defining Header and Background of the Printer Report

Allows import and use of logos for custom printer report headers and backgrounds.

Activating/Deactivating an Automatic Printout

Configures whether reports are printed automatically after measurements.

Setting Sample List Options

Defines parameters for managing sample lists and automatic naming conventions.

Installing User Accounts and Passwords

Manages user access, roles, and security settings for the instrument.

User Groups, Auto Logon, Naming Rules and Password Rules

Defines user roles, auto-login behavior, and naming/password policies.

Creating, Editing and Deleting User Accounts

Procedures for managing individual user accounts and their permissions.

Checking, Adjusting and Calibrating the Instrument

Definitions

Provides definitions for key terms related to instrument checks, adjustments, and calibration.

Checks

Details procedures for performing routine checks to ensure instrument accuracy.

Editing the Check Settings

Allows customization of check parameters like tolerance and intervals.

Performing Density Checks

Step-by-step guide for conducting density checks using standard liquids.

Viewing, Printing or Exporting Current Check Data

Methods for accessing, outputting, and archiving check history data.

Adjustments

Procedures for recalibrating the instrument to maintain measurement accuracy.

Performing an Air/Water Adjustment

Instructions for performing a fundamental air/water adjustment of the density module.

Performing a Temperature Range Adjustment

Guides on adjusting the instrument for optimal accuracy across a range of temperatures.

Performing a High Density/High Viscosity Adjustment (DMA 5000 M only)

Specific adjustment procedures for high-density and high-viscosity samples on DMA 5000 M.

Performing an Atmospheric Pressure Adjustment

Instructions for adjusting the instrument's built-in atmospheric pressure sensor.

Performing Special Adjustments

Details on performing custom adjustments for specific density units and conditions.

Special Adjustments

General overview and prerequisites for performing special density adjustments.

Special Adjustment for the Canadian Excise Alcohol Table

Specific procedure for adjusting the instrument for Canadian excise alcohol calculations.

Viewing, Printing or Exporting Adjustment Data

Methods to review, print, or export historical adjustment data.

Viewing, Printing or Exporting Adjustment History: KB Graph

Accessing and outputting adjustment history data in graphical format.

Resetting the Adjustment Data to Factory Adjustment

Procedure to revert the instrument's adjustments to factory default settings.

Calibrating

Guides on performing calibration using certified standard liquids to validate accuracy.

Defining and Using Methods

Measuring Methods

Explains the structure and content of measurement methods configured on the instrument.

Changing Methods

Covers creating, editing, and managing measurement methods.

Defining Measuring Settings

Sets parameters like measurement type, temperature, and timeout for each method.

Defining the Displayed Output Fields

Customizes which data fields are shown on the main screen for a method.

Defining the Result Output

Selects the output quantities for printouts and data exports for a method.

Defining Limits

Sets upper and lower limits for parameters to trigger warnings.

Defining Multiple Measurements

Configures the instrument to perform multiple measurements automatically for averaging.

Defining Formula Parameters

Sets parameters for API calculations and special adjustments.

Defining Quick Setting Parameters

Configures quick access parameters for rapid measurement adjustments.

Creating, Deleting, Hiding and Arranging Methods

Manages the creation, removal, visibility, and order of measurement methods.

Selecting the Method

Explains how to choose and activate a specific measurement method.

Measuring

General Sample Settings

Sets default parameters for sample measurements, including type and naming.

Using the "No Sample List" Mode

Describes operation when no sample list is active, using quick settings.

Using the "Sample List" Mode

Explains how to use the sample list feature for managing multiple samples.

Filling Samples

Provides essential techniques for filling the measuring cell accurately and without bubbles.

Performing Measurements

Outlines the steps to initiate and conduct a measurement.

Filling and Measurement Errors

Addresses potential errors during sample filling and measurement, including status messages.

Status Messages

Explains the meaning of various status messages displayed during measurement.

Error Messages

Details error messages, particularly related to automatic bubble detection.

Cleaning and Storing the Instrument

Cleaning and Drying the Measuring Cell

Provides instructions for the proper cleaning and drying of the instrument's measuring cell.

Storing the Instrument

Guidelines for safely storing the instrument when not in use.

Cleaning the Instrument Housing and Touch Screen

Procedures for cleaning the exterior housing and the touch screen interface.

Handling the Measurement Data

Defining the Data Memory Settings

Configures how measurement data is stored and managed in the instrument's memory.

Defining Data Columns for the Data Browser

Customizes the data fields displayed in the data browser view.

Viewing Results

Explains how to access and view stored measurement results.

Filtering Results

Details how to apply filters to narrow down displayed or exportable measurement data.

Viewing Statistics

Describes how to access and interpret statistical analysis of measurement data.

Printing and Exporting Results and Other Data

Instructions for printing reports and exporting data in various formats.

Deleting Results

Procedures for removing stored measurement results from the instrument.

Using Special Functions

System Security

Manages security settings to protect data and prevent unauthorized access.

Security Level

Configures the overall security level, including compliance options.

Auto Logoff and Password Expiry

Sets automatic user logoff times and password validity periods.

Increased Security

Activates enhanced security measures beyond standard levels.

Audit Trail

Enables logging of all instrument operations for traceability and integrity.

Electronic Signature

Implements electronic signatures for authenticating data entries and operations.

User Functions - Constants, Formulas, Polynomials and Tables

Describes creating custom calculations and data transformations.

Calculator

Provides a built-in calculator for simulating functions and performing basic calculations.

Group Calculator

Allows simultaneous calculation of multiple related values.

Service Utilities

Making a Backup of the Instrument Settings

Instructions for creating a backup of all instrument configurations and settings.

Restoring Instrument Settings

Guides on restoring instrument settings from a previously created backup file.

Updating the Firmware

Procedures for updating the instrument's firmware to the latest version.

Viewing the System Information

Accessing details about the instrument's hardware, firmware, and configuration.

Viewing and Printing Live Raw Data

Allows viewing and outputting real-time sensor data from the instrument.

Communication with External PC and LIMS

Connecting the Instrument to an External PC via Ethernet

Details how to establish network connectivity using Ethernet for PC communication.

Connecting the Instrument to an External PC via RS-232

Instructions for connecting the instrument to a PC using the RS-232 serial interface.

Connecting the Instrument to a LIMS

Information on integrating the instrument with a Laboratory Information Management System (LIMS).

Technical Data

Measuring Performance

Specifications related to the instrument's measurement capabilities and accuracy.

Wetted Parts

Lists materials that come into contact with samples and cleaning liquids.

General Technical Data

Provides overall technical specifications including dimensions, weight, and interfaces.

Measuring Special Samples

Degassing Samples

Methods for removing dissolved gases from liquid samples before measurement.

Special Filling Techniques

Techniques for handling challenging sample types like viscous liquids or pastes.

Measuring under Special Conditions

Measuring at High Humidity/Low Temperature Conditions

Addresses challenges and solutions for measurements in humid or low-temperature environments.

Measuring at Low/High Temperatures

Guidelines for performing measurements at temperatures outside the standard range.

Measuring at High Pressures

Procedures for operating the instrument under elevated pressure conditions.

Measuring in Harsh Environments

Tips for operating the instrument in challenging environmental conditions.

Adjusting the Camera Settings

Adjusting the Camera Position

Instructions for optimizing the camera's view of the measuring cell.

Setting the Camera Illumination

Adjusts the camera's lighting for better image quality.

Trouble Shooting

List of Output Quantities

List of Quick Settings Parameters

Bar Codes for Assigning Methods

Density Tables

Firmware Versions

Declaration of Conformity

Menu Tree

Related product manuals