Installing the PowerVInstalling the PowerV
Installing the PowerVInstalling the PowerV
Installing the PowerV
iew Interiew Inter
iew Interiew Inter
iew Inter
faceface
faceface
face
A 61.5 cm (24") RJ45 cable is provided in the intelligence
modules bay. It is used to connect the PowerView to the Power
Array. Use the following procedure to install the PowerView
interface onto the frame:
1. Remove the grill cover from the top level of the frame.
2. Feed the end of the RJ45 cable through the center slot of
the grill cover. Replace the grill cover. See figure 5-11.
Fig 5-11 PowerView Cable Through The Top Grill Cover
3. Connect the RJ45 plug into the receptacle on the back of
the PowerView as shown in figure 5-12.
Fig 5-12 Attach the Cable to the PowerView
5. Position the PowerView over the mounting post on the
front of the frame, and push straight down. The PowerView
snaps into place. See figure 5-13.
6. Tuck the excess cable into the grill cover.
Fig 5-13 Install PowerView On The Frame
Remote Placement of the PowerView
Follow these steps to install the PowerView user interface in a
remote location:
Note: A 6.1m (20') Remote RJ45 cable is included with the
Symmetra
TM
Power Array.
1. Connect the Remote RJ45 cable to the communication
port at the rear of the Power Array frame. See figure 1-10.
2. Connect the other end of the cable to the receptacle at the
rear of the PowerView. See figure 5-12.
Note: The short length of RJ45 cable that is hardwired to the
Power Array frame can be safely coiled and placed on top of the
redundant intelligence module.
3. Replace the grill cover.
The PowerView can sit upright on a flat surface by folding
out the wire bail on the back. It can also be mounted onto a
wall.
Wall Mounting the PowerView
Follow these steps to install the PowerView on a wall:
1. Note the four mounting slots molded into the back of the
PowerView interface.
2. Use the template in figure 5-14 to secure four large screws
on a clean dry wall surface.
3. Leave the head of each screw 8mm (5/16") out from the
surface of the wall. Screws must be strong enough to sup-
port 6.8kg (15lb).
4. Mount the PowerView display onto the wall by position-
ing it over the screws and sliding it down until it is securely in
place.