CONNECT TVSS
Back-UPS
®
RS 1000
User’s Manual
Back-UPS
®
RS 1500
1
®
CONTENTS
RJ-45USB
RJ-11RJ-11
2
CONNECT BATTERY CARTRIDGE
4
CONNECT EQUIPMENT / POWER
Monitor
Printer or Scanner
FAX
External Disk or
CD / DVD Drive
10
INSTALL SOFTWARE ON
COMPUTER
There are four status indicators (lights) on the
front panel of the Back-UPS (On Line, On
Battery, Overload, and Replace Battery).
On Line (green) - is lit whenever utility
power is powering the Battery Backup
outlets.
On Battery (yellow) - is lit whenever the
battery of the Back-UPS is powering
equipment connected to the Battery
Backup Outlets.
Four Beeps Every 30 Seconds - this
alarm is sounded whenever the Back-UPS
is running On Battery. Consider saving
work in progress.
Overload (red) - is lit whenever power
demand has exceeded the capacity of the
Back-UPS.
Continuous Tone - this alarm is sounded
whenever the Battery Backup outlets are
overloaded.
Circuit Breaker - the circuit breaker button
located on the rear panel of the Back-UPS
will stick out if an overload condition forces
the Back-UPS to disconnect itself from
utility power. If the button sticks out,
disconnect non-essential equipment. Reset
the circuit breaker by pushing the button
inward.
Replace Battery (red) - is lit whenever the
battery is near the end of its useful life, or
if the battery is not connected (see above).
A battery that is near the end of its useful
life has insufficient run-time and should be
replaced.
Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has
failed the automatic diagnostic test.
Continuous Beeping - this alarm is
sounded whenever a low battery condition
is reached. Battery run-time is very low.
Promptly save any work in progress and
exit all open applications. Shutdown the
operating system, computer and the Back-
UPS.
NOTE: Macintosh Users - for full USB
performance, use OS 9.22 or higher.
If Autoplay is not enabled on the computer,
proceed as follows:
1. On the computer desktop of the display,
double-click on My Computer.
2. Double-click on the CD-ROM drive icon
and follow the on-screen instructions.
11
GROUND
The Back-UPS features a transient
voltage surge-suppression (TVSS)
screw for connecting the ground lead
on additional surge suppression devices
such as network and data line surge
protectors.
Wall
Outlet
Modem/
Phone/Fax
TVSS GND
From Data Line
TVSS
Follow the
on-screen
instructions.
On Line
On Battery
Overload
Replace Battery
w
w
w
.apc.com
®
STATUS INDICATORS AND ALARMS
SERVICE
If the Back-UPS arrived damaged, notify the
carrier.
If the Back-UPS requires service, do not
return it to the dealer. The following steps
should be taken:
1. Consult the Troubleshooting section to
eliminate common problems.
2. If the problem persists, go to http://
www.apc.com/support/.
3. If the problem still persists, contact APC
Technical Support.
4. Have the Back-UPS model number, serial
number and date of purchase available. Be
prepared to troubleshoot the problem with an
APC Technical Support representative. If
this is not successful, APC will issue a
Return Merchandise Authorization (RMA)
number and a shipping address.
7
To Computer USB
Port
CONNECT INTERFACE CABLE
Data Port
BR24BP Batter y Pack
Computer
RJ-45USB
For connection of APC’s optional
external 24-volt battery pack
(BR24BP) to the Back-UPS RS 1000
3
5
Phone Jack
Computer
Modem Port
CONNECT PHONE/MODEM/FAX
TVSS GND
Wal l
Outlet
Wal l
Outlet
Modem/
Phone/Fax
6
CONNECT 10/100 Base-T or VOIP
Network Jack
Computer
Network Port
Note: Allow the Back-UPS to charge for a
full eight (8) hours prior to use.
Press the front panel Power ON/OFF switch
and observe that the following events occur
after pressing and releasing the switch:
The green On Line indicator flashes.
The yellow On Battery indicator lights
while a Self-Test is being performed.
When Self-Test has successfully
completed, only the green On Line
indicator will be lit.
If the internal battery cartridge is not
connected (see Step 2 above), the green
On Line indicator and red Replace Battery
indicators will light. The Back-UPS will
also emit a chirping sound.
8
SWITCH ON THE BACK-UPS
9
ORIENTATION
10/100 Base-T
VOIP
✘✔
Computer
3
OPERATING ENVIRONMENT
32 - 104
o
F (0 - 40
o
C)
24 inches
60 cm
BATTERY
BACKUP
SURGE ONLY
OR
and Back-UPS RS 1500.
Question and Answer IconNeed help?

Do you have a question about the APC RS 1500 and is the answer not in the manual?

Summary

Operating Environment

Temperature Range

Specifies the acceptable operating temperature range for the Back-UPS device.

Ventilation Requirements

Details the necessary clearance around the Back-UPS for proper ventilation.

Connecting Equipment and Power

Connect Equipment; Power

Guidance on connecting computers, printers, or external drives to the Back-UPS.

Connect Phone;Modem;Fax

Instructions for connecting telephone, modem, or fax lines to the Back-UPS for surge protection.

Connect 10;100 Base-T or VOIP

Steps for connecting network cables (Ethernet or VOIP) to the Back-UPS.

Connect Interface Cable

Information on connecting the Back-UPS to a computer using a USB interface cable.

Connect TVSS Ground

How to connect the ground lead for additional surge suppression devices.

Initial Setup and Operation

Connect Battery Cartridge

Procedure for connecting the internal battery cartridge to the Back-UPS unit.

Switch On the Back-UPS

Instructions on how to power on the Back-UPS and initial status indicators.

Install Software on Computer

Guidance for installing the Back-UPS management software on a computer.

Status Indicators and Alarms

On Line Indicator

Explanation of the green 'On Line' indicator light status.

On Battery Indicator

Meaning of the yellow 'On Battery' indicator light.

Overload Indicator

Description of the red 'Overload' indicator and its meaning.

Replace Battery Indicator

Indication for the red 'Replace Battery' light.

Battery Operation Alarms

Audible alarms indicating battery operation, low battery, or failed diagnostics.

Circuit Breaker

Information about the rear panel circuit breaker and overload reset.

Troubleshooting and Service

Troubleshooting Common Problems

Lists common issues with the Back-UPS and their corrective actions.

Order Replacement Battery Cartridge

Instructions and part number for ordering replacement battery cartridges.

Transfer Voltage and Sensitivity Adjustment

How to adjust the Back-UPS transfer voltage and sensitivity settings.

Service and Contact Information

Steps to take if the Back-UPS requires service and APC contact details.

Summary

Operating Environment

Temperature Range

Specifies the acceptable operating temperature range for the Back-UPS device.

Ventilation Requirements

Details the necessary clearance around the Back-UPS for proper ventilation.

Connecting Equipment and Power

Connect Equipment; Power

Guidance on connecting computers, printers, or external drives to the Back-UPS.

Connect Phone;Modem;Fax

Instructions for connecting telephone, modem, or fax lines to the Back-UPS for surge protection.

Connect 10;100 Base-T or VOIP

Steps for connecting network cables (Ethernet or VOIP) to the Back-UPS.

Connect Interface Cable

Information on connecting the Back-UPS to a computer using a USB interface cable.

Connect TVSS Ground

How to connect the ground lead for additional surge suppression devices.

Initial Setup and Operation

Connect Battery Cartridge

Procedure for connecting the internal battery cartridge to the Back-UPS unit.

Switch On the Back-UPS

Instructions on how to power on the Back-UPS and initial status indicators.

Install Software on Computer

Guidance for installing the Back-UPS management software on a computer.

Status Indicators and Alarms

On Line Indicator

Explanation of the green 'On Line' indicator light status.

On Battery Indicator

Meaning of the yellow 'On Battery' indicator light.

Overload Indicator

Description of the red 'Overload' indicator and its meaning.

Replace Battery Indicator

Indication for the red 'Replace Battery' light.

Battery Operation Alarms

Audible alarms indicating battery operation, low battery, or failed diagnostics.

Circuit Breaker

Information about the rear panel circuit breaker and overload reset.

Troubleshooting and Service

Troubleshooting Common Problems

Lists common issues with the Back-UPS and their corrective actions.

Order Replacement Battery Cartridge

Instructions and part number for ordering replacement battery cartridges.

Transfer Voltage and Sensitivity Adjustment

How to adjust the Back-UPS transfer voltage and sensitivity settings.

Service and Contact Information

Steps to take if the Back-UPS requires service and APC contact details.

APC RS 1500 Specifications

General IconGeneral
Nominal Output Voltage120V
TopologyLine interactive
Waveform TypeStepped approximation to a sinewave
Input Voltage120V
Nominal Input Voltage120V
Input ConnectionsNEMA 5-15P
Output Power Capacity865 Watts / 1500 VA
Input Frequency50/60 Hz
Battery TypeSealed lead-acid battery (maintenance-free)
Output Connections(8) NEMA 5-15R
Cord Length1.83 meters
Interface Port(s)USB
Operating Temperature0 - 40 °C
Operating Humidity0-95% non-condensing
Safety ApprovalscUL Listed, FCC Part 15 Class B, UL 1778