CONNECT TVSS
User’s Manual
Back-UPS
®
XS 1500
1
2 4
CONNECT BATTERY CARTRIDGE OPERATING ENVIRONMENT
3
7
CONNECT EQUIPMENT / POWER
Monitor
Printer or Scanner
FAX
External Disk or
CD / DVD Drive
Input: 120V~
12A, 60Hz
Circuit Breaker
Push to Reset
SURGE
ONLY
BATTERY
BACKUP
Computer
8
CHECK BUILDING WIRING
FAULT INDICATOR
Building
Wiring Fault
Wall
Outlet
Modem/
Phone/Fax
TVSS GND
Building Wiring
Fault Indicator
6
Phone Jack
Computer
Modem Port
CONNECT PHONE/
TVSS GND
Wal l
Outlet
Modem/
Phone/Fax
9
To Computer USB
Port
CONNECT INTERFACE CABLE
Data Port
BR24BP Battery Pack
Computer
12
INSTALL SOFTWARE ON
COMPUTER
There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery, Overload,
and Replace Battery).
On Line (green) - is lit whenever utility power is
powering the Battery Backup outlets.
On Battery (yellow) - is lit whenever the battery of
the Back-UPS is powering equipment connected to the
Battery Backup Outlets.
Four Beeps Every 30 Seconds - this alarm is
sounded whenever the Back-UPS is running On
Battery. Consider saving work in progress.
Overload (red) - is lit whenever power demand has
exceeded the capacity of the Back-UPS.
Continuous Tone - this alarm is sounded
whenever the Battery Backup outlets are
overloaded.
Circuit Breaker - the circuit breaker button
located on the rear panel of the Back-UPS will
stick out if an overload condition forces the Back-
UPS to disconnect itself from utility power. If the
button sticks out, disconnect non-essential
equipment. Reset the circuit breaker by pushing
the button inward.
Replace Battery (red) - is lit whenever the battery is
near the end of its useful life, or if the battery is not con-
nected (see above). A battery that is near the end of its use-
ful life has insufficient run-time and should be replaced.
Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has failed
the automatic diagnostic test.
Note: Allow the Back-UPS to charge for a full
eight (8) hours prior to use.
Press the front panel Power ON/OFF switch and
observe that the following events occur after
pressing and releasing the switch:
The green On Line indicator flashes.
The yellow On Battery indicator lights while
a Self-Test is being performed.
When Self-Test has successfully completed,
only the green On Line indicator will be lit.
If the battery cartridges are not connected (see
Step 3 above), the green On Line indicator
and red Replace Battery indicators will light.
The Back-UPS will also emit a chirping
sound.
Continuous Beeping - this alarm is sounded
whenever a low battery condition is reached.
Battery run-time is very low. Promptly save any
work in progress and exit all open applications.
Shutdown the operating system, computer and
the Back-UPS.
NOTE: Macintosh Users - for full USB performance,
use OS 9.22 or higher.
If Autoplay is not enabled on the computer, proceed
as follows:
1. On the computer desktop of the display, double-
click on My Computer.
2. Double-click on the CD-ROM drive icon and
follow the on-screen instructions.
If the rear panel Building Wiring Fault (red) indicator
is lit, a potential shock hazard exists due to one of the
following conditions:
• Open or high resistance ground
• Hot or neutral polarity reversed
• Overloaded neutral circuit
Improper building wiring should be corrected by a
qualified electrician. Do not use the Back-UPS until
the condition that caused the fault is corrected.
Note: Improper building wiring will not prevent the
Back-UPS from operating, but it will limit its
protection capability.
11
SWITCH ON THE BACK-UPS
10
ORIENTATION
13
GROUND
The Back-UPS features a transient
voltage surge-suppression (TVSS)
screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.
Wal l
Outlet
Modem/
Phone/Fax
TVSS GND
From Data Line
TVSS
Follow the
on-screen
instructions.
On Line
On Battery
Overload
Replace Battery
w
w
w
.apc.com
®
RJ-45USB
STATUS INDICATORS AND ALARMS
32 - 104
o
F (0 - 40
o
C)
✘✔
A
3
24 inches
60 cm
5
CONNECT BACK-UPS TO
BATTERY PACK
Data Port
Building
Wiring Fault
Wall
Outlet
Modem /
Phone/Fax
TVSS GND
BR24 BP Batt ery Pack
MODEM/FAX
INSTALL PEDESTAL
EXTENDER
Align
Slide Together
INSTALL BACK-UPS AND
BATTERY PACK IN PEDESTAL
B
Question and Answer IconNeed help?

Do you have a question about the APC XS 1500 and is the answer not in the manual?

Summary

APC Back-UPS XS 1500 Installation

Install Pedestal Extender

Steps to install the pedestal extender for the Back-UPS.

Install Back-UPS and Battery Pack in Pedestal

Procedure for installing the main unit and battery pack into the pedestal.

Connect Battery Cartridge

Instructions on how to connect the internal battery cartridge.

Operating Environment

Recommended environmental conditions for operating the Back-UPS.

Connect Back-UPS to Battery Pack

Steps for connecting the main Back-UPS unit to the battery pack.

Connect Phone;Modem;Fax

Guidance on connecting phone, modem, or fax lines for surge protection.

Connect Equipment; Power

Instructions for connecting various types of equipment to the Back-UPS outlets.

Check Building Wiring

Information on the building wiring fault indicator and potential issues.

Connect Interface Cable

How to connect the Back-UPS to a computer using an interface cable.

Orientation

Recommended physical orientation for the Back-UPS unit.

Switch On the Back-UPS

Procedure for powering on the Back-UPS and initial self-test.

Install Software on Computer

Steps to install the necessary software on a computer for full functionality.

Connect TVSS Ground

Instructions for connecting transient voltage surge suppression ground leads.

Status Indicators and Alarms

Status Indicators Overview

Explanation of the front panel indicators: On Line, On Battery, Overload, Replace Battery.

Alarm Conditions Explained

Descriptions of audible alarms and their causes (e.g., on battery, overload, low battery).

Troubleshooting Guide

Common Back-UPS Problems and Solutions

Lists common issues like unit not switching on, no power during outage, or short backup time.

Order Replacement Battery Cartridge

Guidance on ordering a new battery cartridge and its typical lifespan.

Replace Battery Cartridge Procedure

Visual Guide for Battery Replacement

Step-by-step illustrations showing how to replace the battery cartridge.

Specifications and Settings

Technical Specifications

Detailed technical specifications including voltage ranges, load capacity, and dimensions.

Transfer Voltage and Sensitivity Adjustment

Instructions for adjusting the Back-UPS's transfer voltage and sensitivity settings.

Service and Support

Service and Warranty Information

Procedures for obtaining service, warranty details, and limited warranty terms.

Contact Information

Contact details for APC Technical Support via internet, phone, and fax.

APC XS 1500 Specifications

General IconGeneral
Nominal Output Voltage120V
Nominal Input Voltage120V
Input ConnectionsNEMA 5-15P
Typical Recharge Time8 hours
Waveform TypeStepped approximation to a sinewave
Interface Port(s)USB
Output Connections8 NEMA 5-15R
Cord Length1.83 meters
Battery TypeSealed Lead-Acid
Input Frequency50/60 Hz
Audible AlarmAlarm when on battery
Transfer Time8 ms typical
Weight11.0 kg
Dimensions302 x 112 x 382 mm