APC RS 800 - User Manual

APC RS 800
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
0
/
1
0
0
B
a
s
e
-
T
/
V
O
I
P
CONNECT TVSS
Back-UPS
®
RS 800
User’s Manual
2
OPERATING ENVIRONMENT
3
CONNECT EQUIPMENT / POWER
Monitor
Printer or Scanner
FAX
External Disk or
CD / DVD Drive
Computer
4
CHECK BUILDING WIRING
FAULT INDICATOR
Building Wiring
Fault Indicator
5
Phone Jack
CONNECT PHONE/MODEM/FAX
7
CONNECT 10/100 Base-T
6
To Computer USB
Port
CONNECT INTERFACE
Computer
9
INSTALL SOFTWARE ON
COMPUTER
There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery, Overload,
and Replace Battery).
On Line (green) - is lit whenever utility power is
powering the Battery Backup outlets.
On Battery (yellow) - is lit whenever the battery of
the Back-UPS is powering equipment connected to the
Battery Backup Outlets.
Four Beeps Every 30 Seconds - this alarm is
sounded whenever the Back-UPS is running On
Battery. Consider saving work in progress.
Overload (red) - is lit whenever power demand has
exceeded the capacity of the Back-UPS.
Continuous Tone - this alarm is sounded
whenever the Battery Backup outlets are
overloaded.
Circuit Breaker - the circuit breaker button
located on the rear panel of the Back-UPS will
stick out if an overload condition forces the Back-
UPS to disconnect itself from utility power. If the
button sticks out, disconnect non-essential
equipment. Reset the circuit breaker by pushing
the button inward.
Replace Battery (red) - is lit whenever the battery is
near the end of its useful life, or if the battery is not con-
nected (see above). A battery that is near the end of its use-
ful life has insufficient run-time and should be replaced.
Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has failed
the automatic diagnostic test.
Note: Allow the Back-UPS to charge for a full eight (8)
hours prior to use.
Press the front panel Power ON/OFF switch and observe
that the following events occur after pressing and
releasing the switch:
The green On Line indicator flashes.
The yellow On Battery indicator lights while
a Self-Test is being performed.
When Self-Test has successfully completed,
only the green On Line indicator will be lit.
If the internal battery cartridge is not
connected (see Step 1 above), the green On
Line indicator and red Replace Battery
indicators will light. The Back-UPS will also
emit a chirping sound.
Continuous Beeping - this alarm is sounded
whenever a low battery condition is reached.
Battery run-time is very low. Promptly save any
work in progress and exit all open applications.
Shutdown the operating system, computer and
the Back-UPS.
NOTE: Macintosh Users - for full USB performance,
use Mac OS 10.1.5 or higher.
If Autoplay is not enabled on the computer, proceed
as follows:
1. On the computer desktop of the display, double-
click on My Computer.
2. Double-click on the CD-ROM drive icon and
follow the on-screen instructions.
If the rear panel Building Wiring Fault (red)
indicator is lit, a potential shock hazard exists
due to one of the following conditions:
• Open or high resistance ground
• Hot or neutral polarity reversed
• Overloaded neutral circuit
Improper building wiring should be
corrected by a qualified electrician. Do not
use the Back-UPS until the condition that
caused the fault is corrected.
Note: Improper building wiring will not
prevent the Back-UPS from operating, but it
will limit its protection capability.
8
SWITCH ON THE BACK-UPS
10
GROUND
The Back-UPS features a transient
voltage surge-suppression (TVSS)
screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.
From Data Line
TVSS
Follow the
on-screen
instructions.
On Line
On Battery
Overload
Replace Battery
RJ-45USB
STATUS INDICATORS AND ALARMS
or VIOP
CABLE
TVSS GND
Modem/Fax/Phone
Wall
Outlet
Data Port
Building Wiring F ault
Circuit Breaker
Push to Reset
Input: 120V~
12A, 50-60Hz
BATTERY BACKUP
SURGE ONLY
TVSS GND
Modem/Fax/Phone
Wall
Outlet
Data Port
Building Wiring Fault
TVSS GND
Modem/Fax/Phone
Wall
Outlet
Data Port
TVSS GND
Modem/Fax/Phone
Wall
Outlet
CONNECT BATTERY CARTRIDGE
1
(Back-UPS RS models only)
Computer
Modem Port
Modem/
Wall
Outlet
Data Port
1
0
/
1
0
0
B
a
s
e
-
T
/
V
O
I
P
To 120 VAC, 50-60 Hz
Back-UPS
®
XS 800
Network Jack
Computer
Network Port
32 - 104
o
F (0 - 40
o
C)
30 cm
w
w
w
.apc.com
®
(optional)
Question and Answer IconNeed help?

Do you have a question about the APC RS 800 and is the answer not in the manual?

Summary

Connect Battery Cartridge

Operating Environment

Connect Equipment; Power

Check Building Wiring Fault Indicator

Connect Phone;Modem;Fax

Connect Interface Cable

Connect 10;100 Base-T or VIOP

Switch On the Back-UPS

Install Software on Computer

Connect TVSS Ground (optional)

Status Indicators and Alarms

On Line Indicator

Green light indicates utility power is supplying the Battery Backup outlets.

On Battery Indicator

Yellow light indicates battery power is supplying the Battery Backup outlets.

Overload Indicator

Red light indicates power demand exceeds the Back-UPS capacity.

Replace Battery Indicator

Red light indicates battery is near end of life or not connected.

Four Beeps Every 30 Seconds Alarm

Alarm sounds when Back-UPS is running on battery; save work in progress.

Continuous Beeping Alarm

Alarm sounds at low battery; save work, exit apps, and shut down.

Continuous Tone Alarm

Alarm sounds when Battery Backup outlets are overloaded.

Circuit Breaker Reset

Button pops out on overload; push to reset after disconnecting equipment.

Chirps for 1 Minute Every 5 Hours Alarm

Alarm sounds if battery fails the automatic diagnostic test.

Summary

Connect Battery Cartridge

Operating Environment

Connect Equipment; Power

Check Building Wiring Fault Indicator

Connect Phone;Modem;Fax

Connect Interface Cable

Connect 10;100 Base-T or VIOP

Switch On the Back-UPS

Install Software on Computer

Connect TVSS Ground (optional)

Status Indicators and Alarms

On Line Indicator

Green light indicates utility power is supplying the Battery Backup outlets.

On Battery Indicator

Yellow light indicates battery power is supplying the Battery Backup outlets.

Overload Indicator

Red light indicates power demand exceeds the Back-UPS capacity.

Replace Battery Indicator

Red light indicates battery is near end of life or not connected.

Four Beeps Every 30 Seconds Alarm

Alarm sounds when Back-UPS is running on battery; save work in progress.

Continuous Beeping Alarm

Alarm sounds at low battery; save work, exit apps, and shut down.

Continuous Tone Alarm

Alarm sounds when Battery Backup outlets are overloaded.

Circuit Breaker Reset

Button pops out on overload; push to reset after disconnecting equipment.

Chirps for 1 Minute Every 5 Hours Alarm

Alarm sounds if battery fails the automatic diagnostic test.

APC RS 800 Specifications

General IconGeneral
TopologyLine Interactive
Waveform TypeStepped approximation to a sinewave
Battery TypeSealed lead-acid battery (maintenance-free)
Weight11.8 kg
Dimensions (H x W x D)432 x 95 x 330 mm