Do you have a question about the Aprilaire 1750 and is the answer not in the manual?
Model | 1750 |
---|---|
Voltage | 115V |
Dehumidification Capacity | 70 pints per day |
Moisture Removal Capacity | 70 pints per day |
Filter Type | MERV 8 |
Drainage | Gravity Drain |
Humidity Control Range | 35% to 70% RH |
Emphasizes adherence to all applicable codes for safe installation.
Specifies dedicated circuit needs for 1750 (15A) and 1770 (20A) models.
Details correct transportation and required 24-hour settling period for compressor integrity.
Highlights risks of electrical shock, cuts from sharp edges, and potential injury from unit weight.
Explains the unit's role in home humidity control and its air cycling/ventilation capabilities.
Provides technical details on size, weight, airflow, and operating conditions.
Offers guidance on placement and environmental considerations for optimal operation.
Details collar installation, recommended duct types, pressure, and sealing methods.
Instructions for installing the drain trap and connecting the condensate line properly.
Guidelines for hanging the unit using unistruts and ensuring filter access.
Describes how to connect the dehumidifier with the HVAC system for whole-home humidity management.
Details the wiring diagram for connecting the dehumidifier to HVAC controls.
Explains the dip switch and dial settings for various operational modes.
Outlines using the dehumidifier for humidity control in targeted areas like basements or crawlspaces.
Shows the wiring diagram for localized installation with thermostat and HVAC.
Describes dip switch and dial settings for localized operation modes.
Details setup for prioritizing specific zones and then managing whole-home humidity.
Explains wiring for system dampers and the 24 VAC transformer.
Covers dip switch and dial settings for convertible zoned operation.
Instructions for setting up periodic HVAC fan activation for air circulation.
Details how to use an outdoor air damper for fresh air intake and ventilation.
Provides the formula and table for determining minimum ventilation CFM based on room size and bedrooms.
Guides on measuring static pressure to determine actual airflow delivery.
Explains how to set cycle period and time based on airflow requirements and tables.
Describes wiring a normally closed float switch for leak protection and compressor disabling.
Details the purpose and operation of each system setup dip switch.
Outlines essential checks for wiring and component functionality before system startup.
Explains LED indicators and behavior during test mode for diagnostics.
Addresses issues like no airflow, hot air, poor dehumidification, and drainage problems.
Solves problems with dampers not opening or continuous fan cycling.
Addresses ventilation damper failures and compressor non-operation.
Explains how the dehumidifier operates based on HVAC calls and set cycle periods.
Describes how dampers control airflow in central and zoned installation configurations.
Details how ventilation and air cycling are activated based on settings and HVAC system status.