EasyManua.ls Logo

Aprilaire E070 - User Manual

Aprilaire E070
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Model E070
70 PPD Professional-Grade,
Crawl Space DehumidierDehumidier
INSTALLATION & OWNER'S MANUAL
Installed By: Installer Phone: Date Installed:
PLEASE LEAVE THIS MANUAL WITH THE DEHUMIDIFIER OWNER
Product Info &
Digital Manual
English 1

Other manuals for Aprilaire E070

Questions and Answers

  • D
    danielallenAug 18, 2025
    What to do if Aprilaire E070 Dehumidifier shows E7 error?
    • K
      kylebennettAug 18, 2025
      If the Aprilaire Dehumidifier displays error code E7, empty the condensate pan and check the float switch connection at the control board. If you are not using a float switch, verify that a jumper is between the float switch terminals on the dehumidifier control board. If the problem persists, replace the float switch.
  • B
    Barbara DavisAug 20, 2025
    What does error E2 mean on my Aprilaire E070?
    • U
      uwatkinsAug 20, 2025
      If the Aprilaire Dehumidifier displays error code E2, verify that the fan works and there is no blocked or restricted ductwork. If the fault persists, call Technical Support.
  • S
    Scott JacksonAug 23, 2025
    What does error E3 mean on my Aprilaire E070?
    • E
      eric27Aug 23, 2025
      If the Aprilaire Dehumidifier displays error code E3, check connections between the Model 76 and the dehumidifier control board. Ensure terminals are fully inserted and secured. If connections are correct, turn off the dehumidifier and remove the Model 76. Reconnect the Model 76 to the control board with a short 4-wire cable. Turn the dehumidifier back on and increase the dryness level setting on the Model 76. If the dehumidifier turns on, the problem is with the wiring. If it doesn't, call Technical Support.
  • T
    Tina TurnerAug 26, 2025
    What does error E4 mean on my Aprilaire E070?
    • C
      cwolfAug 26, 2025
      If the Aprilaire Dehumidifier displays error code E4, check the frost sensor connection at the power board, ensuring the terminal is fully seated. Remove the side access panel and verify the sensor is secured to the suction line. If connected and secured, reset the fault by cycling power. Turn the humidity setting down to make a dehumidification call. Let the fan and compressor run for 10-15 minutes, then enter diagnostic test mode by pressing the UP ARROW and MODE buttons for 3 seconds. Record the displayed values and call Technical Support.
  • J
    Jose WaltersAug 28, 2025
    What does error E5 mean on my Aprilaire E070 Dehumidifier?
    • J
      Jason GravesAug 28, 2025
      If the Aprilaire Dehumidifier displays error code E5, check the high temperature sensor connection at the power board, ensuring the terminal is fully seated. Remove the side access panel and verify the sensor is not damaged and is connected to the refrigeration line coming from the compressor. If the sensor is connected and secured to the refrigeration line, contact Technical Support.
  • J
    Jay JohnsonAug 30, 2025
    What does error E6 mean on my Aprilaire E070?
    • D
      Derek MillerAug 31, 2025
      If the Aprilaire Dehumidifier displays error code E6, check the low temperature sensor connection at the power board. Remove the side access panel and verify the sensor is not damaged and is connected to the suction line. If the sensor is connected and secured to the refrigeration line, contact Technical Support.
  • M
    Michelle Collins PhDSep 2, 2025
    What does error E1 mean on my Aprilaire Dehumidifier?
    • O
      oboyerSep 2, 2025
      If the Aprilaire Dehumidifier displays error code E1, cycle power to clear the error code. If the error code reappears, replace the User Interface, Part No. 5475.
  • F
    franklinerikSep 4, 2025
    Why is my Aprilaire E070 producing hot air?
    • J
      Joshua RoweSep 5, 2025
      The air is reheated across the condenser coil, which results in a temperature rise between the inlet and outlet. This is normal operation for the Aprilaire Dehumidifier.
  • K
    Kevin JordanSep 7, 2025
    What to do if my Aprilaire Dehumidifier blower is running but with little or no airflow?
    • M
      Michael SanchezSep 7, 2025
      If the blower is running with little or no airflow, the pressure drop across the dehumidifier may be higher than 0.4"w.c. Try checking the Aprilaire Dehumidifier's air filter and wash or replace it. Also, inspect the ductwork for any blockages and clear them.
  • S
    Susan LucasSep 9, 2025
    What to do if my Aprilaire E070 Dehumidifier is not draining properly?
    • L
      Lindsay FuentesSep 9, 2025
      If your Aprilaire Dehumidifier is not draining properly, verify that the unit is level. Also, check the drain line for any blockages and ensure it has a continuous downward slope.

Summary

Safety Instructions

Operating the Dehumidifier

Installing the Dehumidifier

Wiring

Wiring to a Float Switch

Connecting the dehumidifier to a float switch or condensate pump overflow switch.

Wiring to Remote Control

Connecting a remote control like the Model 76 for setting adjustment.

Installer Setup

Setting Up Remote Control - Crawl Space;Sealed Attic

Enabling remote control functionality with a Model 76 for specific installation types.

Starting Up the Unit and Sequence of Operation

Troubleshooting

Diagnostic Codes

Interpreting error codes displayed on the unit for fault identification and resolution.

Aprilaire E070 Specifications

General IconGeneral
ModelE070
CategoryDehumidifier
Coverage AreaUp to 2, 800 sq. ft.
Energy Star CertifiedYes
Control TypeDigital
TypeWhole House
Voltage115V
CFM200 CFM
RefrigerantR-410A
Capacity70 Pints
DrainageGravity Drain
Humidity Control Range40% to 80%

Related product manuals