2
SAFETY INSTRUCTIONS
WARNING
Do not use
solvents/cleaners
on or near the
circuit boards.
CAUTION
OVERVIEW
SPECIFICATIONS
Dimensions: 20
3
4”W x 24”L x 20
3
8”H (mounting feet fully engaged)
20
3
4”W x 24”L x 23
5
8”H (mounting feet fully extended)
Weight: 1750A–93 lbs. 1770A–100 lbs.
Capacity: 1750A–90 pints per day @ 60%RH, 80°F
1770A–135 pints per day @ 60%RH, 80°F
(ANSI/AHAM DH-1-2003 conditions)
Power: 1750A–115 VAC, 8 Amps. 1770A–115 VAC, 14 Amps.
Unit is equipped with an 8 ft. grounded power cord.
This Aprilaire Central Dehumidifier is designed specifically to control humidity inside the whole home as well as in crawlspaces
and attics. This dehumidifier automatically and continually measures the true measure of moisture level, dew point. The unit
operates to control humidity to the dryness set point that is either set on the unit or on the optional living space control.
A built-in, automatic air cycling feature can be utilized to activate the HVAC fan to cycle the air throughout the whole home for
proper balance for comfort. See Air Cycling, page 10, for more details on this feature.
This dehumidifier also has a patented, built-in ventilation feature, which will allow fresh air to be brought into the home from the
outside. In utilizing this feature, the dehumidifier will dehumidify the incoming air, if needed (based on dew point / dryness set
point), as the outside air is first entering the home. The built-in ventilation feature is designed to be able to meet ASHRAE 62.2
Standard for Ventilation. See Ventilation, page 10, for more details on this feature.
LOCATION NOTES
Design Airflow: 1750A–275 CFM @ 0.6 in. w.c.
1770A–500 CFM @ 0.6 in. w.c.
Filter: MERV 8 Filter
Cabinet Insulation: 1” foil faced EPS insulation
Inlet Air Operating Conditions: 40°F to 105°F
Ambient Air Operating Conditions: 40°F to 150°F
This product must be installed by a qualified heating and air conditioning contractor.
Failure to do so could result in serious injury from electrical shock or damage to product.
120 volts may cause serious injury from electric shock. Disconnect electrical power
before starting installation. Leave power disconnected until installation is completed.
Sharp edges may cause serious injury from cuts. Use care when cutting plenum
openings and handling ductwork.
Unit weight and dropping may cause personal injury or equipment damage.
Handle with care.
In coastal areas, due to high concentrations of salt and other corrosive material present in the air, it is recommended to use a
Model 70 Living Space Control. Please note the dehumidifier is not meant to be used in pool applications.
Note the following installation requirements:
REQUIREMENT
APPLICATION LOCATION
ATTIC GARAGE BASEMENT CRAWLSPACE
All ductwork must be insulated and sealed
Drain pan with overflow protection should be placed under the unit
to prevent water damage in the event of a drain failure
Condensate line should be insulated to prevent external
condensation on the line
Ensure the unit does not operate in conditions
below 40°F or above 150°F