READ AND SAVE THESE INSTRUCTIONS
Safety &
Installation
Instructions
TABLE OF CONTENTS
Installation location recommendations.............2
Outdoor temperature sensor (included).............2
Remote temperature sensor (optional) .............3
Thermostat mounting...........................3
Power & reset options..........................4
Wiring terminal ...............................4
INSTALLATION
SETUP & TESTING
REFERENCES
WIRING DIAGRAMS
Equipment type selection switch (SW1) ............7
Installer setup menu ...........................7
Change system settings.........................7
HVAC installer system settings table ............8-9
Indoor Air Quality system settings tables..........10
Air cleaning sytem settings table ..............10
Humidifier system settings table ...............10
Dehumidifier system settings table .............11
Ventilation system settings table............11-12
Climate map for ASHRAE fresh air setup ..........12
Removal of Indoor Air Quality control buttons ......13
System test menu .........................13-14
System test tables.........................15-16
Quick reference to controls & display.............17
Troubleshooting ..............................18
Error codes ..................................19
Thermostat features ..........................19
Specifications................................20
Conventional heat/cool single transformer..........5
Conventional heat/cool two transformer ...........5
Heat pump single transformer....................5
Heat pump two transformer .....................5
Indoor Air Quality equipment – dehumidifier . . . . . . . . 6
Indoor Air Quality equipment – humidifier . . . . . . . . . . 6
Indoor Air Quality equipment – ventilation..........6
Model 8620 Thermostat with
Event-Based
Air Cleaning and
Humidity or Ventilation Control

Other manuals for Aprilaire 8620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aprilaire 8620 and is the answer not in the manual?

Aprilaire 8620 Specifications

Operating Environment IconOperating Environment
control range temperature40º to 99ºF (4º to 37ºC)
display range temperature32º to 99ºF (0º to 40ºC)
storage temperature-30º to 140ºF (-34.4º to 60ºC)
operating humidity5% to 90% relative humidity (non-condensing)
operating ambient temperature32º to 120ºF (0º to 48.9ºC)
shipping temperature range-30º to 140ºF (-34.4º to 60ºC)
Power IconPower
ac voltage24 VAC (18-30 VAC)
ac power18-30 Volt AC
dc power3.0 Volts DC (2 “AA” Alkaline batteries included)
maximum load per terminal1 amp
total maximum load2.5 amp
Screen IconScreen
screen size10.3 sq. in.
screen backlightFully back lit w/ constant low intensity light option
Weight and Dimensions IconWeight and Dimensions
height4 15/16”
width6”
depth1 5/16”