CHAPTER 3
UNIT DESCRIPTION
Entire Contents Copyright 2004 by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
APS-1000 Series 3 - 5 OM-001-01000-000-04.0
Voltage Selection
VOLTAGE display Displays the:
Selected voltage value when Output is OFF.
• Voltage value during voltage adjustment.
• Output voltage during normal operation.
• System parameters during SYSTEM / PROGRAM set-up.
150V indicator When ON, the system is in low-voltage range (0 - 150 VAC).
300V indicator When ON, the system is in high-voltage range (0 - 300 VAC).
OUTPUT / RESET
indicator
• When ON, the system is in normal operation.
• When BLINKING, the system has encountered an error.
LOW / HIGH button Located below the two voltage range indicators; toggles voltage range.
OUTPUT / RESET
button
• Toggles System Output ON/Off, under normal operation.
• Resets the System after an Output error has occurred.
button
Steps the output voltage down; SYSTEM / PROGRAM parameter select.
︿ button
Steps the output voltage up; SYSTEM / PROGRAM parameter select.
APS-1000 Voltage Display
V O L T A G E
OUTPUT
/ RESET
0-150
0-300