23
The maximum open circuit voltage rating of the PV module must be within the operating voltage
range of the microinverter.
The maximum current rating at MPP is recommended to be equal to or less than the maximum
input DC current, but the maximum short circuit current must be equal to or less than the maximum
input DC short circuit current.
The output DC power of PV module is NOT recommended to exceed 1.35 times the output AC
power of the microinverter. Refer to “Aptos Warranty Terms & Conditions” for more information.
8.1 DC Input
8.2 AC Output
8.3 Efficiency, Safety, and Protection
Commonly used module power (W)
(singe panel)
Peak power MPPT voltage range (V)
34~48
22
Operating voltage range (V)
16~60
Maximum input voltage (V)
60
Maximum input current (A)
2*12.5
Maximum input short circuit current (A)
2*15
800
Maximum continuous output power (VA)
766
Maximum continuous output current (A)
3.68@208V
3.19@240V
Nominal output voltage/range (V)
208/183-229
240/211-264
Nominal frequency/range (Hz)
55-65 (under 60Hz @ 220V & 230V)
>0.99 default
0.8 leading……0.8 lagging
Output current harmonic distortion
<3%
Maximum units per 20A branch
4@208V
5@240V
© 2021 Aptos Solar Technology, LLC. All rights reserved.
MAC
TM
800R
96.70%
96.50%
99.80%
MAC
TM
800R
MAC
TM
800R
Up to 500