EasyManua.ls Logo

Aqua Simpool pH - Annex E: Default Parameter Settings

Aqua Simpool pH
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simpool pH model INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump ENGLISH
ADSP7000407 rev. 1.2 27/03/2015 71/313
ANNEX E - Default Parameters
Default Parameters Table
Parameter IT
Parameter EN
Meaning
Value
A.bu
b.En
Buzzer Enabling
YES
A.In
In.E
Inhibiting Signal
enabling
YES
A.PH
A.PH
OFA Alarm Activation
(minimum variation)
0.05 pH
B.P.P
P.P.b
pH Proportional Band
1.5 pH
doS
doS
Operating Mode (Alkaline/Acid)
ACI
LIn
LAn
Language
En
OFA
OFA
Overdosage Alarm time/OFA
Alarm Activations
OFF (disabled)
O.F.d
O.F.d
Maintenance Time
0 sec (disabled)
OnA
OnA
On-line OFA Alarm
YES
OnC
OnC
On-line Calibration
YES
Ond
Ond
On-line Dosage
YES
OnS
OnS
On-line Setpoint
YES
Ont
Ont
On-line Temperature
YES
PAS
PAS
Password
000
P.PH
PHP
PH Cycle Period
300 sec
r.PH
r.PH
Return from OFA Alarm
0.2 pH
SEt
SEt
pH setpoint
7.2 pH
Stb
Stb
Stabilization Time
10 sec
St.P
P.St
Pump Stop (due to Level
Alarm)
no (disabled)
°C
°C
Temperature
noA (25°C)