TECHNOPOOL
Dosing systems for swimming pools ENGLISH
ADSP7000570 rev. 2.0 06/08/2021 11/37
3.1.1 Manual activation of pumps and solenoid valve
The priming sub-menu can be accessed from the user menu, which allows the manual operation of pumps and
solenoid valve.
To access this menu, press key F for 3 seconds; the following options will be displayed:
First Product (it is not displayed on pH/Rx, pH/ClJ and pH/HP Technopool3)
Press keys ▼▲ to set manually the values to be dosed and Enter to confirm and activate
the dosing of the P1 pump.
The dosing that can be set is 0÷999 ml or 1.0÷9.9 litres.
pH corrector
Press keys ▼▲ to set manually the values to be dosed and Enter to confirm and activate
the dosing of the pH pump.
The dosing that can be set is 0÷999 ml or 1.0÷9.9 litres.
Second Product (it is displayed on Time/pH/Time Technopool3)
Press keys ▼▲ to set manually the values to be dosed and Enter to confirm and activate
the dosing of the P2 pump.
The dosing that can be set is 0÷999 ml or 1.0÷9.9 litres.
Rx/Cl/HP corrector (it is not displayed on Time/pH and Time/pH/Time Technopool3)
Press keys ▼▲ to set manually the values to be dosed and Enter to confirm and activate
the dosing of the Rx/Cl/HP pump.
The dosing that can be set is 0÷999 ml or 1.0÷9.9 litres.
Solenoid valve priming (it is not displayed on Time/pH Technopool3)
Press keys ▼▲ to set manually the opening schedule of the solenoid valve and Enter to
confirm and activate its opening.
The schedule that can be set is 0÷50 seconds (at steps of 10 seconds) or 1÷60 minutes
(at steps of 1 minute).
Temperature (is displayed only if the temperature is not set on OFF)
Press keys ▼▲ to set the required temperature, only if the temperature has been set manually.
The temperature can be set at 0÷100° C.
Press key F for 3 seconds to exit the priming menu, or exit automatically after a minute without pressing any key.