4.8 SETTING THE CYCLIC DOSING ( PUMP)
(it is displayed for Time/pH/Time technopool3)
Depending on whether the temperature has been programmed, the following parameters must be set for the pump
operation for the cyclic dosing:
Temperature OFF (disabled):
Qty Sec. Prod. Frq. sec. Prod. Hour sec. Prod
Manual temperature or with PT100:
Qty sec. Prod. Qty sec. P. TMax Frq. sec. Prod. Hour sec. Prod.
Enter the installer menu, select option Set Point/Timer and press key Enter.
Temperature OFF (disabled):
Qty sec. Prod.
Indicates the quantity to be dosed in ml or litres.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷999 ml or 1.0÷9.9 litres.
Frq. sec. Prod.
Indicates the activation frequency of the pump dosing, which can be set in hours
or days.
Values that can be set are 1÷23 hours or 1÷7 days (d).
Hour sec. Prod. (only if the frequency has been programmed in days)
Indicates the activation hour. If it is left in Auto, the activation occurs
immediately after the programming.
Values that can be set are 0÷23 hours or Auto.
Example:
Sec. Prod. Qty = 400 ml
Sec. Prod. Freq. = 2 d
Sec. Prod. Hour = 13
The system activates P2 pump to dose 400 ml of product every two days at
h13.00.
Manual temperature or with PT100:
Qty sec. Prod.
Indicates the quantity to be dosed in ml or litres.
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷999 ml or 1.0÷9.9 litres.
Qty sec. P. TMax
Indicates the quantity to be dosed (0÷999 ml or 1.0÷9.9 litres) to the
programmed maximum temperature value (23÷36°C)
Press keys ▼▲ to set the desired value and Enter to confirm.
Values that can be set are 0÷999 ml or 1.0÷9.9 litres.
Frq. Sec. Prod.
Indicates the activation frequency of the pump dosing, which can be set in hours
or days.
Values that can be set are 1÷23 hours or 1÷7 days (d).
Hour sec. Prod. (only if the frequency has been programmed in days)
Indicates the activation hour. If it is left in Auto, the activation occurs
immediately after the programming.
Values that can be set are 0÷23 hours or Auto.